I think there's some confusion on what this actually looks like on the manufacturer's end. When charging a lithium battery, your termination point is tied to o
by calamari4065 3y ago
I think there's some confusion on what this actually looks like on the manufacturer's end.
When charging a lithium battery, your termination point is tied to only one value: voltage. 4.2v per cell is generally considered the maximum safe termination voltage. This is the theoretical 100% charge. And yes, if you keep pushing volts in, it will keep taking them until the call fails catastrophically.
Personally, I use 4.1 as my termination voltage. That's somewhere around 90-95%. You 'lose' a little of the maximum capacity, but lifespan is increased. I find it's fairly common for battery charge controllers to use either 4.1 or 4.2 as their default termination, but it's almost always selectable. You have to make a decision somewhere.
The flaw in this is that you're trading away a banner spec for something that users won't appreciate. You have to decrease the stated capacity and runtime of your battery in exchange for an indefinable amount of extra total lifetime. That's not something that consumers can/will take into account. They just look for the device with the most mAh or runtime.