3 ms·
> As devices like home fridges move towards “inverter drive” with switch mode power supplies, I wonder how low of a voltage they could still run off. And if the
by mschuster91 3y ago
> As devices like home fridges move towards “inverter drive” with switch mode power supplies, I wonder how low of a voltage they could still run off. And if they’d happily accept 48VDC and still function.
The technical side should continue to work until you reach the lower limit of what the bootstrap circuitry can handle.
The problem will be the amperages required... say, a fridge. Its motor will run at ~200 watts, which means 1A at 230V. No biggie. But if you're going down to 48V, the high-voltage side will now run 4A, and more the lower you go on voltage - and that's without taking peak inrush currents into account which can easily go to 10A@230V (or 40A@48V) for a few split seconds. If your current source or the wiring can't hold that, you'll likely run into serious issues.
- sokoloff 3y agoI thought one major advantage of inverter drives was the well-managed starting currents. This is a noise/vibration advantage but also an electrical win.
- hinkley 3y agoBut a wire pulling 2 amps at 3.3 volts experiences very different physics than a wire pulling .6 amps at 12 volts.
- quickthrowman 3y agoInrush current is much less of an issue with a VFD/inverter driven motor then a motor controlled by a basic DOL motor starter. ABB claims that the inrush current of their VFDs is 100-150% of the motor FLA, which lines up nicely with the NEC rule to size motor conductors at 125% of the FLA of the motor. A typical DOL/across the line starter has an inrush current 6-7x higher than the FLA. https://library.e.abb.com/public/71d5526a71b34360bb3a258c950acb8a/LVD-EOTN151U-EN_VFDs_And_Maximum-Inrush-Current.pdf https://library.e.abb.com/public/71d5526a71b34360bb3a258c950...