Let us leave aside how much more readily a vertical stack lends itself to ground mounting compared to a flat array for now. Gravity loads are not typically the
by brudgers 15y ago
Let us leave aside how much more readily a vertical stack lends itself to ground mounting compared to a flat array for now.
Gravity loads are not typically the primary concern for conventional solar arrays, uplift is. Deadload is an effective means of counteracting uplift. Lateral force per unit area on a roof mounted object is significantly less than uplift (and lest we forget, the length of the lever is mid height for a uniformly distributed load.
Roof design is like computer security, every penetration in the membrane is a potential site of infiltration. More holes = more probability of bulk water in the building. One of the worst places to direct bulk water is around electrical equipment.
Flat layouts create additional problems in regards to maintenance. Access to penetrations and the the membrane will be more largely dependent on the ease with which panels can be demounted, in addition access to panels in the center of the array may also be dependent upon demounting panels - one probably does not want to walk across an energized electrical grid and solar panels tend to be energized when the sun is shining. Hail and wind borne debris are banes of roof mounted arrays and flat panels are generally at significantly greater risk to both.
One ignores that solar panels are a part of a building's electrical system at their own peril, quite literally. A flat scheme not only requires significantly more conductors, it also increases the area over which the potential for a lethal shock is high quite significantly - talk to a fire fighter sometime about how one plans for operations around solar arrays during daylight hours.
It may be reasonable to consider that a longer diurnal period in which significant power is generated will reduce the need for storage capacity - lead acid batteries, hydrogen tanks, and other standard storage methods all come with significant life safety concerns.
Finally, packaged technical solutions tend to provide better quality, lower cost, and a higher degree of safety compared to custom site built solutions. One can assemble a tower in an enclosed factory using industrial Q.C. processes. Doing so on a pitched surface ten meters above grade as light fades at the end of a cold winter day is a bit more unlikely.
This is not to say that the claims of the article are accurate. But from a building science standpoint, a vertical array is a significantly better option than a flat one.
- jacquesm 15y agoI beg to differ. I've done a substantial number of rooftop installations on 45 degree sloped roofs and water never was a problem, even a decade later it still isn't. The thing that matters most is that the mount is solid, not how many mounting points you've got. Contrast that with the freestanding arrangements that I've seen that were literally nothing but trouble. Especially on trackers (see picture above, and that was (and is) definitely one of the better trackers on the market). Most rooftop solar installations are retrofits, so the building is not designed with a solar installation in mind. The general way of doing this is to mount an aluminum subframe to the roof using stand-offs and stainless steel bolts. Copious butyl sealant will take care of any water worries you might have, inspections are typically done every five years. Bigger worries are having to - in North America at least - reshingle a roof. The mounting is done in such a way that it meets up with the studs underneath the plywood in the roof. If you wanted to do that with too few attachment points they'd have to be so strong that the joist underneath would be the limiting factor. Electical wiring is run along the back of the array, then passes to the aluminum frame and slips under the eaves into a conduit into the premises (which is then foamed up to avoid moisture and air from getting into / out of the building). The aluminum subframe is then grounded to avoid lightning troubles. (if a panel or the subframe gets a direct hit it can be very interesting if you forgot this step). The whole installation sits only a few inches away from the roof itself, very little space for the wind to get a grip and you can easily limit that further with a skirt around the edge. Anybody that messes with a solar system when the sun is out will be able to tell you tales of arc welding with the sun. I agree with the access issue, that is one of the reasons why the more clever arrangements include a hinge at the lower end so the panel array can be stood up in case there is every any trouble.
- brudgers 15y agoThe spray and pray method of water management is perhaps the building science equivalent of my code. Commercial buildings are not just scaled up houses in the same way that Github isn't a scaled up version of what someone created for Geocities. Thus, the reason globs of magic goop are not a viable solution to my bulk water management concerns. Bad things can happen when you have to put buckets in a server room or surgical suite. I suspect you might be surprised at the pathways by which bulk water can enter a building without causing structural failure when a hurricane passes by. I will add that your understanding of roof uplift forces is a bit more intuitive than scientific. Objects are sucked off, allowing air to move beneath them has the potential to reduce uplift because the pressure differential is reduced - something one is allowed to consider when designing tile roofs.
- jacquesm 15y agoClearly, on a commercial building the budgets are entirely different than for a residential installation. Of course, in that context you are right. And yes objects are sucked off due to the pressure differential but objects are also blown over and this structure looks like a very efficient wind-trap to me which means it will incur significant loads at high wind speeds, far higher than panels mounted in a regular fashion with those forces concentrated in a much smaller area. Btw, there are millions of roof mounted panels in Germany because of subsidies, the biggest problem seems to be that the panels live substantially longer than the roofs they are mounted on...