4 ms·
> solved thet by running the lighting on 220V with sets of two 110V bulbs in series Sounds like an exciting day when one of your bulbs burns out!
by bruckie 3y ago
> solved thet by running the lighting on 220V with sets of two 110V bulbs in series
Sounds like an exciting day when one of your bulbs burns out!
- bitdivision 3y agoBulbs normally burn out open, breaking the circuit. And in the unusual case that they don't, I would imagine the thin wires leading to the filament will melt, also breaking the circuit. And if all else fails you your circuit breaker should flip. If bulbs normally failed short, then you'd have circuit breaker's flipping a lot more often.
- eythian 3y agoThey can be a little spectacular when they fail short. My last incandescent (a bathroom light) did it a few weeks ago, exploding the glass of the bulb and popping the breaker for my downstairs circuit.
- jefftk 3y agoWhy? A burned-out bulb fails open not closed. If it failed closed then a bulb burning out would trip the circuit breaker.
- sokoloff 3y ago> Why? A burned-out bulb fails closed not open. In electrical circuit terminology, "open" means "not connected" while "closed" means "connected/shorted". That's different from direct translation of Chinese (and I think several European languages) where "open the light" means to turn it on (by closing the circuit, naturally). I think it's most common English engineering usage (by far) to say that a burned out lamp fails open [circuit].
- unethical_ban 3y agoTo close a circuit is to connect it, correct? So when the filament burns out, the circuit breaks, which is an open circuit, correct?
- somat 3y agoIf you want exciting look up floating neutral. the neutral grounds both sides of the split phase and mainly serves to carry current when the load on each phase is unbalanced. when the neutral is cut off from ground all current has to be carried by the phase. if the loads are balanced, everything appears fine. when it is not you end up with a spooky electrical system. as now you have a series connection with a built in voltage divider. on one side the voltage will be too high on the other too low.