> mixed were 18 inches apart, unlabeled, used the exact same connector. They were labeled. Same connector - Standardized connectors are safer. Every chemical
by aaron695 3y ago
> mixed were 18 inches apart, unlabeled, used the exact same connector.
They were labeled.
Same connector - Standardized connectors are safer. Every chemical can't have a different connecter. If the truck swaps connectors in and out per location you are mostly back to square one.
The connectors were locked, that's the differential they choose. Except one wasn't, which is the same issue as the truck swapping connectors. It shouldn't have been possible to have two connectors unlocked at once.
> were locked behind the same gate.
Multiple gates creates other issues.
> 18 inches apart
This the problem, multiple gates a distance apart are an issue, but probably the solution. It also allows clear signage on the gate rather than than the 7 characters you can see on the connector label. I count 5 - 7 connections, they can't all be behind a gate, so there is no hard rule.
> compound gate thing
https://www.youtube.com/watch?v=jh2HWT8gPeY https://www.youtube.com/watch?v=jh2HWT8gPeY
They actually want a 'written' policy to stop people coming in. People ram raid gates to get into compounds so they can't be flimsy. In an emergency power could be out and you can be in a car or running while on fire.
- calgarymicro 3y ago> They were labeled Were they? It says they had labels some distance down the pipe, but they weren't labeled at the point where the hoses connected where someone could actually read it. > Every chemical can't have a different connecter. Every chemical doesn't have to have a different connector. Maybe just ones that will cause a dangerous reaction if mixed. > I count 5 - 7 connections, they can't all be behind a gate, so there is no hard rule. Sure. Again, a good rule of thumb would be to separate the ones that could cause rapid death. > They actually want a 'written' policy to stop people coming in. So no fire code issue then.
- aqme28 3y ago> Every chemical doesn't have to have a different connector. Maybe just ones that will cause a dangerous reaction if mixed. The issue is that they're buying chemicals from vendors so they don't necessarily have control of what connectors are on the truck. If you have Bleach in connector A and acid in connector B, you better hope they don't send an acid truck with an A connector. I think having a way to close the fill lines remotely would have at least seriously downgraded the problem.
- calgarymicro 3y agoI doubt every chemical facility uses the same style connector, so at some point in time this information would have had to be communicated to the chemical supplier anyway. And sure, the supplier could just happen to send the truck with the exact right connector for the other chemical (though that wouldn't be a problem if they just moved the inlets apart), but that's a lot less likely than a screw up when the connectors are the same. I'm not saying (and I doubt the CSB is either) that any of this would eliminate the possibility of incidents. The point is that they'd become much less likely.