3 ms·
Their website mentions the sensor they use directly on the kits page. It's a Plantower PMS5003 which does actually count particles: https://www.aqmd.gov/docs/d
by jauer 3y ago
Their website mentions the sensor they use directly on the kits page.
It's a Plantower PMS5003 which does actually count particles: https://www.aqmd.gov/docs/default-source/aq-spec/resources-page/plantower-pms5003-manual_v2-3.pdf https://www.aqmd.gov/docs/default-source/aq-spec/resources-p...
- dhhagan 3y agoWhile the spec sheet does say that, it's not actually true. The PMS5003 is a truncated nephelometer (https://amt.copernicus.org/articles/15/655/2022/ https://amt.copernicus.org/articles/15/655/2022/) that measures the total scattered light from all particles with diameters less than ~1 µm. This single scalar value (proportional to the total scattered light, as collected across a wide viewing range) is then correlated to a reference measurement of PM2.5 and typically correlates quite well in most urban areas where PM2.5 and PM1 are highly correlated. For more info on the difference between particle counters and nephelometers in this context, see https://amt.copernicus.org/articles/13/6343/2020/ https://amt.copernicus.org/articles/13/6343/2020/.
- jauer 3y agoTIL! Thank you for the detailed explanation and links to additional context.