3 ms·
Covered that already: > Powering the control boards / fans with a generator (or even UPS in a pinch) is a lot simpler proposition than trying to generate enoug
by nucleardog 3y ago
Covered that already:
> Powering the control boards / fans with a generator (or even UPS in a pinch) is a lot simpler proposition than trying to generate enough power to heat my house, water, and food with resistive heating.
My furnace runs on 120V power pulling ~8A when running. That's ~1kW. Comparable sized resistive heating would use about 9kW.
1kW for a few hours a day is easy to provide through a cheap generator, a couple small solar panels and a single marine battery, or apparently a ~$220 wind turbine I can order on Amazon that can output up to 1200W. 9kW is a whole different ball game.
And that's just heating. My stove uses in the order of single-digit watts for seconds at a time. It can also just be lit with a match without power. My water heater does run a small exhaust fan while it's heating, but again... we're talking hundreds of watts instead of kilowatts.