3 ms·
Interesting. Is there a good consise page detailing the main differences between this and older standards? Stuff like cost and ease of maintenance comparisons?
by giantg2 4y ago
Interesting. Is there a good consise page detailing the main differences between this and older standards? Stuff like cost and ease of maintenance comparisons?
- itake 4y agoI’m also curious if there is a path to upgrade existing homes to this standard or do you have to demolish and rebuild (which is not legal in many cities).
- amateuring 4y agono, it's just a feel good PR campaign
- jabart 4y agoThings switched from insulating the wall cavity to insulating the outside of the house. Engineers started to factor in the insulation value of a 2x6 compared to the insulation it was next to and the heat loss in cold climates. Same applies for hot climates. Now these homes are being wrapped in insulation on the outside with all joints sealed, then insulated on the inside and essentially pressure tested for air leaks. The houses can be "tight" enough that you have to have a system to cycle in fresh air in a way that it heats/cools it with the air that is leaving. You also need a makeup air vent for things like a stove hood. There is a new system that before drywall goes up, they pressurize the house and spray a caulk in the air that finds its way to all the pinhole leaks and seals them to further reduce air leaks during the building process.
- TrueSlacker0 4y agoHow will I get to experience opening up a wall in the house I have lived in for a decade to find McDonalds trash stuck in the wall instead of insulation?
- ortusdux 4y agoHeat exchangers are a big one, but they are not yet that common in the US. They are used to pre-heat the makeup air. I'm looking into one atm as part of a HVAC upgrade as currently running a bath fan with all the windows closed will draw air down the chimney.
- bluGill 4y agoHeat exchangers have been code for more than 20 years. Maybe not common, but only because there are a lot of old houses. Or maybe where you live didn't adopt the new code?
- giantg2 4y agoI have a house that's less than 20 and it doesn't have a heat exchanger. I haven't heard of the new construction around here having any. Perhaps it's only in certain states?
- bluGill 4y agoI'm most familiar with Minnesota of 20 years ago, which being a cold area does tend to adopt cold weather codes quicker than others.
- oh_sigh 4y agoI understand you can just check the pressure during a blower test to see if there are leaks, but how do they actually identify where the leaks are? Go around all over the house with a smoke gun?
- Syonyk 4y agoIf there's a good thermal difference between interior temperature and exterior temperature, a thermal imager will help catch an awful lot of the leaks.
- mikeyouse 4y agoLargely yes. You don't need to survey every inch though since leaks aren't present in the middle of walls, but typically at complex areas (around windows, roof penetrations, can lights, outlets, rim joists, etc) so a little smoke quickly IDs those issue areas. Another way way to find leaks is to run the blower door tests on a day where there's a large temperature differential (ideally when it's very cold outside). You can use a thermal camera before the test and then after you depressurize the house for a 10 or 15 minutes - the leaky areas are perfectly obvious on the thermal since the cold outdoor air is washing over the walls near the leaks. Taking the before/during thermal videos on a walkthrough lets you compare the side-by-side later on and ID which spots need attention.
- amluto 4y ago> You have to have a system to cycle in fresh air in a way that it heats/cools it with the air that is leaving. This is quite nice regardless. Houses are unlikely to be so drafty that the air inside is always fresh, and a real ventilation system will deliver fresh, filtered air all the time. > You also need a makeup air vent for things like a stove hood. You need this anyway, at least in CA, if your hood exceeds 400cfm, and it’s probably a good idea regardless. Sadly, high end hoods seem to mostly have way too much airflow, and decent makeup air systems are rare and complex.
- Gibbon1 4y ago> Things switched from insulating the wall cavity to insulating the outside of the house. Oh good they finally figured that out. Cause that's where you want the stuff. And insulating a bunch cavities is labor intensive.
- amluto 4y agoI’m not at all convinced that exterior insulation would have lower labor cost. You have to competently install sheets of rigid insulation, and then you need to competently install siding over it. Insulating cavities needs some skilled labor if you use mineral wool, but a skilled installer goes fast. Or you can use some kind of blown in product, which takes very little labor. (I have never seen competently installed fiberglass batts. I’m not sure they really exist.)
- mikeyouse 4y agoInsulting cavities well is immensely labor intensive and unfortunately is still required in homes with exterior insulation so you're kind of getting the worst of both worlds. Exterior insulation is an absolute breeze in comparison though, there are tons of product on the market that integrate the sheathing and insulation into a single unit so it installs just like any other exterior sheathing would.
- amluto 4y agoI watched a crew install a blown fiberglass product: they stapled fabric over the walls, poked holes in it, and stuck a hose in each hole so a machine in their truck could flow fiberglass into the cavity. It went very quickly and fully filled the cavities. John Mansville Spider Plus looks like another interesting product — blown fiberglass that is just sticky enough that it can supposedly be applied to walls and even ceilings without anything to contain it.
- jabart 4y agoExterior typically requires sheathing and insulation is attached to that sheathing. Extra work is required to tape up the seams though it eliminates the plastic house wrap required in most areas in the US which is attached with staples or a nail gun.
- jws 4y agoThere are tax credits to the builder to offset some of the increased up front cost, $2000 + $500 for some systems, and 22% on PV systems. It looks like the homeowner can get a $5000 tax credit for 10 years. The goal is to transition to housing which can be powered by renewables. To that end there are requirements for the thermal integrity of the envelope and windows, there must be electric run for HVAC heat pumps, hot water heat pumps, and at least one EV parking space. Lighting must be modern high efficiency stuff. Ductwork must be inside the thermal envelope. There are indoor air quality standards to meet.
- Syonyk 4y agohttps://www.energy.gov/eere/buildings/zero-energy-ready-home-program https://www.energy.gov/eere/buildings/zero-energy-ready-home... seems to be the main landing page, and it's a bit handwaving... > A DOE Zero Energy Ready Home is a high-performance home that is so energy efficient that a renewable energy system could offset most or all the home's annual energy use. "Most or all" and "annual energy use" allow for some massive wiggle room. Annual energy use by who? A family with a couple teenage girls is going to likely use a lot more hot water than a family with a three year old boy. I can't find any actual concrete details on it, annoyingly. So I have to agree that it's more of a feel-good listing until proven otherwise.
- giantg2 4y agoI was really interested in the insulation part and building design. The only thing I could find was that it has to be energy star, which is only 10% better insulation than code.
- mikeyouse 4y agoACH2.0 in most of the upper part of the country is pretty aggressive. The 2015 ICC isn't a slouch either -- say you're in Chicagoland building a new home, this would mandate R49 in the attic, R20 in the walls (or R13 in the bays + R5 exterior), R15 on basement walls, R30 in the floors. It could of course be much more aggressive, and likely will be eventually, but if you had a ACH2 house with those insulation values, minimum U-0.3 windows, >0.94 efficient gas furnace / high quality heat pumps, it would be a very efficient house. Table R402.1.2 here: https://codes.iccsafe.org/content/IECC2015/chapter-4-re-residential-energy-efficiency#IECC2015_Pt02_Ch04_SecR402 https://codes.iccsafe.org/content/IECC2015/chapter-4-re-resi...
- smolder 4y agoTo get really high R value on insulation, often that means a 2x6 or 2x8 framed outer wall to allow for the additional thickness needed by the insulation. Double pane windows are well-surpassed by those with many panes and carefully designed frames with low thermal bridging. Aside from more insulation you need great air sealing, across every joint and in every window and door frame. Older construction had no explicit ventilation, just a lot of leaking such that the house "breathed". On modern, efficient homes, the air seal is very tight for efficiency reasons, so you need an ERV/HRV system to exhange air for you to keep the air healthy, while minimizing energy loss for that airflow. Insulating materials used inside the roof and sheathing are typically closed cell foam or rockwool, or in Europe they sometimes use a wood fiber based insulation. There are lots of caulks and adhesive tapes for getting a good air seal, and there's also a technique where one pumps the house frame full of a vapor that reacts across pressure drops and plugs any holes it flows through. Last, well insulated homes can get cheap heating and cooling from modestly sized heat pumps which are very efficient. One zero energy home I saw has heat exchangers on the roof to capture energy from the sun for warm water as well, supplemented by heat pumps powered by photovoltaics.
- bluGill 4y agoModern houses have gone back to 2x4 walls. Then the put 2 inches of foam under the siding so the thickness is equal to a 2x6. There is already on the market standard doors and windows that fit this. Though 4 inches of foam may make more sense yet, but there are no standard doors or windows for that thickness so costs go up.