A side effect of this that people don't consider is not only is the infrastructure not able to handle everyone electrifying their cars, stoves, heat, etc. but t
by nemo44x 4y ago
A side effect of this that people don't consider is not only is the infrastructure not able to handle everyone electrifying their cars, stoves, heat, etc. but that millions and millions of homes don't have enough amperage to support it. Most homes built before the 1980's have 100A service. Most before 1950 had 50A and many still do.
If you consider that charging a couple vehicles while running electric AC/heat and using your 30A induction stove isn't even possible on millions of properties, you begin to see some of the issues. Consider it costs many thousands to upgrade a house and we have a problem. The biggest problem being just who is going to upgrade these homes.
And even if you can there's a greta chance they don't have space in their panel or that they will need a special circuit added to support things. This needs an electrician and costs significant money.
Solvable problem, but people who just say "make it all electric" don't even consider this.
- HALtheWise 4y agoI'm not sure what sort of smart meter integration is required to make this happen, but it would be sweet if the electric car could ramp down or pause it's charging near-instantly when the induction stove or AC kicks on, since those are both intermittent and the car charging can wait.
- brianwawok 4y agoMy EV lets me say "start charging at 11pm" My induction stove is never ever going to run at 11pm.
- nemo44x 4y agoBut maybe you have a couple (or more!) AC units (or heat pumps) that both happen to kick in at the same time at 11pm by chance.
- brianwawok 4y agoSo 100amp service is a "normal" sized house. Your heat pump and AC are what, 30 amps? So it's ok if it kicks on at 11.
- nemo44x 4y agoThat's not really true. 200A has been sent to typical homes the last 30-40 years as our energy needs have increased. A normal sized home in America is 2,400-3,000 SqFt. which probably requires a couple AC units. Already if 2 units are going and the induction stove is running + whatever else in the house, you're already well over 100A. Now factor in that everything will trip at 80% so you don't even get your total load. I highly doubt a 100A system would pass code in the type of configuration you're suggesting. "Trust me, I'll run everything right" isn't good enough. I'd be shocked your 100A panel even has any space left for a new 30A+ circuit.
- brianwawok 4y ago> A normal sized home in America is 2,400-3,000 SqFt. which probably requires a couple AC units I don't understand where you are getting this multiple AC unit thing. My house is 4,700 square feet above grade (2000 more below grade), and I have a single AC. Now it is the absolute biggest, baddest, mode insane residential AC unit my HVAC place makes (5 ton seer 27 I believe).. but it is a single unit. I think I know a single person who has 2 AC units, and their house is a bit smaller than mine (maybe 4500 square feet). If my house were built today it would have 2 ACs.. but again, I am very much on the extreme end of size. And this entire thing is on I believe a 40 amp circuit.
- nemo44x 4y agoThere are millions of old homes that need to be retrofitted for AC. They don’t have duct work because they are heated by radiators. When they are upgraded to have AC they often have 2 (or more) units since running ducts up and down isn’t feasible. So for the first floor you run ducts in the basement and vent up. For second the coil is in the attic if possible and vent down. These types of homes often have 100A service and running 3t + 2t already stress it. People also do it for efficiency reasons. Running hot/cold air long distances is a good way to waste money. It’s also better design to have multiple units and therefore multiple zones. Why are you cooling your bedrooms all day and your living room all night? Installing multiple units is better design but cheap builders just try and keep prices/quotes low to customers that don’t understand it.
- AYBABTME 4y agoA battery would help here to handle the surge. At least that's how I've got it setup on my boat, where my inverters supplement the limited 30A "service" by pulling from the battery when the load goes above 30A.
- zamnos 4y agoThe feeders off the meter just need their own power meter and some smarts and a way to tell the car to pause charging (or just deenergize that circuit). The smarts monitor the circuit that goes to the kitchen, sees that there's been a significant power draw for some amount of time, and then shuts off the car charging circuit. Pretty straightforwards circuit to build from scratch, though I'd recommend just getting a unit that does that.
- brianwawok 4y ago200A service here. At some point may need to upgrade to 400A. I don't think EV charging is a huge deal for many. 20-30A / 240 will usually charge you overnight. You can run it after you are done with the induction stove. I think 100A service can still work for quite a while. Heat pumps are maybe the most iffy thing.
- nemo44x 4y agoYou need to consider in old homes (of which there are millions and will continue to be) things like AC are run in multiple zones since the ducts were added decades after the homes was built it's just easier to have multiple units. Also as the home scales in size you need more units, including heat pumps if you go that route. So you have a couple of these units running at 30/40/50A each and a couple cars plugged in, possibly one of them needs super charging so it's using 50A and someone has 3 induction burners going and the electric dryer is running while your teenager blow dries their hair. Not to mention all the passive things likke the fridge/freezer, lights, charging devices, etc. Point being, at any given time there's a combination of things that could need power and you have to be able to support that.
- brianwawok 4y agoSee other thread. If your house is taking multiple 30 amp AC splits, something is wrong with your setup. Many mini-splits run on 120V 15-amp.. the same plug as a vacuum or microwave. Edit - Also make sure you understand the difference between 120 and 240V circuits. Not entirely clear you do.
- namibj 4y agoWell, do the hard work when drywall comes off for any reason. That should have been done for at least 10 years now, but somehow many lack the foresight/suffer from broken incentives (put in data wiring when you have the opportunity, and bury fiber/speedpipes when you dig a street up. Still, doesn't happen, because broken incentives.)