3 ms·
BMCs have to be some of the most unreliable devices that I've worked with. Some of the issues I encountered at my last job: * [ASRock BMC] The BMC firmware upd
by chenxiaolong 4y ago
BMCs have to be some of the most unreliable devices that I've worked with. Some of the issues I encountered at my last job:
* [ASRock BMC] The BMC firmware updater sometimes causes the NICs to get stuck in a bad state where every NIC has the same MAC address. This can be resolved via a proprietary UEFI application for reflashing the correct MAC address.
* [Dell iDRAC] Local authentication randomly stops working due to some tmpfs running out of space (can see the message if there's an active SSH session). IPMI/SSH occasionally works well enough to issue a reboot command, but when it doesn't, sending the BMC reset comand to /dev/ipmi0 in the server OS is needed.
* [Dell iDRAC] Setting an asset tag via the IPMI DCMI command has a 15 character limit. If that limit is exceeded, the success response is still returned, but when querying the asset tag, random junk data longer than 15 bytes is returned. If I had to guess, I bet there was an sprintf() call somewhere in there :). This was fixed in newer iDRAC firmware. Now, it stores the last 15 bytes of the asset tag instead of returning an error.
* [Lenovo IMM] The shift or alt key sometimes gets stuck on the emulated keyboard without having used the remote console since the last BMC reboot. Can't be fixed by repressing the button, neither physically nor via the virtual keyboard. BMC reboot required.
* [Lenovo IMM] Booting the UEFI shell sometimes crashes both the system and the BMC.
* [Lenovo IMM] BMC and BIOS update sometimes claims to have succeeded, but didn't actually take effect.
* [Lenovo IMM] Rebooting the BMC via the web UI or SSH sometimes doesn't work. Making 50+ simultaneous requests to the login page is enough to crash and restart some component that allows the BMC reboot command to work again though.
* [Supermicro BMC] The BIOS update sometimes doesn't fully upload, but claims that it did. It still parses the header, so the new/old version fields look correct. Sometimes, rebooting the BMC and reflashing works. Other times, only a USB drive + USB keyboard + a recovery key combination fixes it.
* [Supermicro BMC] The remote console sometimes completely fails to initialize (though I've only seen this on servers where the BMC uptime was measured in years). Not just a blank screen. The GPU device was just... gone.
* [Supermicro BMC] Various IPMI commands just lie about successful execution. For example, setting the asset tag via the FRU succeeds, but has no effect. Those commands require toggling a write lock bit via an OEM command, which I only found by reverse engineering. Other commands, like the set asset tag DCMI command, leave the data in a corrupted state until a BMC reboot.
And finally, not really a bug, but an interesting thing about the Lenovo IMM. Instead of exposing information via standard IPMI features, like FRU or DCMI commands, the Lenovo IMM implements a virtual filesystem over OEM IPMI commands. These are commands, like (my naming) open_ro, open_rw, get_size, read, write, and close. They sometimes fail too. I think I ended up making all commands retry up to 10 times with a 5 second delay. At least Lenovo gets error return values right :).
To query the asset tag, you have to open_ro the "config.efi" file, get the size (because read-until-EOF doesn't always work), do a read loop, and close the file. Then, you have the XML data from the file you can query (20 seconds later due to retries). (If anyone ever needs to deal with the Lenovo IMM programmatically, I'd highly recommend the pyghmi [1] library. Wish I knew about it before reverse engineering their proprietary commands...)
[1] https://opendev.org/x/pyghmi https://opendev.org/x/pyghmi
- justsomehnguy 4y ago> * [Supermicro BMC] The BIOS update sometimes doesn't fully upload, but claims that it did. Or uploads it to the WebGUI but balks with a different errors. Flash with SUM from SuperDoctor SET IP=192.168.128.20 SET USER=ADMIN SET PASS=ADMIN .\SUM -i %IP% -u %USER% -p %PASS% -c UpdateBios --file E:\Shares\Temp\x10sle-f\bios.bin --force_update --reboot .\SUM -i %IP% -u %USER% -p %PASS% -c GetBmcInfo * [Supermicro BMC] BMC on a dedictated Ethernet port get moved to the Shared LAN port on the blade reboot. Which also means what if did shutdown the machine then you no longer can power up it remotely.
- ilyt 4y ago> * [Supermicro BMC] Various IPMI commands just lie about successful execution. For example, setting the asset tag via the FRU succeeds, but has no effect. Those commands require toggling a write lock bit via an OEM command, which I only found by reverse engineering. Other commands, like the set asset tag DCMI command, leave the data in a corrupted state until a BMC reboot. we have Supermicro server with serial flashed to be something like 12345678 which means it probably doesn't work reliably on their production line either lmao