What you say is true, though another approach that could be more efficient is to simply run the heat pumps with a higher setpoint rather than supplementing them
by sokoloff 4y ago
What you say is true, though another approach that could be more efficient is to simply run the heat pumps with a higher setpoint rather than supplementing them with [as much] resistive heat (especially in the majority of season that isn't the coldest design day).
It might "feel wrong" to set the heat pumps to 25°C, but that could easily be cheaper and more efficient than setting them to 20-21°C and supplementing to the same level of comfort with CoP of 1 resistive heating all season long.
- MonkeyMalarky 4y agoI have the same setup as GP and setting a higher temp doesn't help at all. My thermopump is in the main hallway on the second floor and blows towards the master and second bedroom, above the stairs. In summer it's great because it sends cold air everywhere and lets it sink to first floor. In winter, it just creates an insufferable hot bubble on the second floor. I already prefer to sleep in the cold and just use baseboard heaters on the main floor and bathroom. I don't even heat my bedroom.
- BizarroLand 4y agoSounds like a ceiling fan or some sort of air circulator is in order. If you put a ceiling fan on blow to push the hot air down it will blend with the air in the rest of your house and improve the overall comfort of your space. If that won't work, for instance your home is very boxy and separated, it might be worth looking into AC duct boosters on the far away areas to suck more air out of the ducts from farther away. If I misunderstood and you have a ductless system, they make electric fans that go in between paired walls and look like a ducted register, but that are very useful for blending air between two rooms. A few of those alongside a through floor to ceiling below fan duct might be available that could help even out temps in your house even more.
- SketchySeaBeast 4y agoDo heat pumps not just work in an "on/off" fashion that shut off when the thermostat say "ok, that's enough"? I know that modern forced air natural gas furnaces are a little smarter and will have stages to balance for noise, but they are really just "on" or "off", pushing much hotter than ambient air around until the rooms settle to the desired temperature.
- sokoloff 4y agoMost heat pumps now are variable speed/output. I suspect all low-outside temp capable heat pumps are variable speed/inverter drive.
- SketchySeaBeast 4y agoIs the speed/output a high/medium/low type deal or a specific temperature?
- sokoloff 4y agoThe outdoor unit can vary the frequency of the compressor drive to track a desired refrigerant temperature in the face of varying load from the indoor unit. As the indoor air comes closer to the desired temperature, it will cool off the returning refrigerant less than when there is a large delta-T. The outdoor unit can adjust the compressor speed to closely match the heat transfer and run continuously at a lower speed rather than cycling on/off. There is a minimum speed below which the compressor can't run [and so would have to cycle], but in general the outside unit is smoothly variable. The indoor unit fan speeds are only loosely connected to this. (The higher the indoor fan speed, the greater the heat transfer and load on the compressor, all else being equal.)