We are thinking of switching some gas appliances to electric in our old farmhouse but we probably need to rework our electrical panel completely to add high amp
by PaulHoule 4y ago
We are thinking of switching some gas appliances to electric in our old farmhouse but we probably need to rework our electrical panel completely to add high amperage services for an induction range (my wife won't accept an ordinary electric range) and an electric water heater.
Fortunately our son is in training as a handyman and that means we can get him working on projects of all kinds around the farm. Of all the trades, electricity is the one that I know enough about to supervise somebody. (e.g. I am baffled by plumbing)
- toomuchtodo 4y agoIf you need to upgrade your service entrance, if it's within your means, go to 400A to future proof (EVs, HVAC and hot water heat pumps, induction stove, and other large loads all add up, along with colocated generation of some sort). Depending on your authority having jurisdiction (AHJ) and utility, they may require a licensed electrician to replace the raceway or similar entrance to the meter. 200A is satisfactory if greater amperage isn't available (US centric advice). Think of this as the residential version of "dig once" [1]. EDIT: Yes, you may not need 400A immediately, but if you're doing an upgrade, the cost delta between the conductors for 200A vs 400A is not substantial except for very long runs. Also, some utilities will cover the cost of a service upgrade to the meter; from the meter onward into the home is your cost. Balance cost with future needs, future labor costs, etc. Very similar to dropping a whole bunch of cheap fiber in a trench just in case you need it in the future. I usually recommend people combine this work with a solar PV install, to capture the 30% federal tax credit towards the work (if you can justify the upgrade as necessary, which you can if your current service is less than 200A), as it has no limit on the amount you can capture as part of the install (versus the previous tax credit for electrical upgrade costs for installing an EV charging station). [1] https://www.fhwa.dot.gov/policy/otps/policy_brief_dig_once.pdf https://www.fhwa.dot.gov/policy/otps/policy_brief_dig_once.p...
- UI_at_80x24 4y agoThis is double-great advice. It's completely obvious once mentioned but not something that may have occurred of the top of ones head. Thank-you for posting.
- bombcar 4y agoIt's strange because 400a service will probably NOT ever be needed, but the cost difference from 100-200 and 100-400 is basically nothing. You can also get a separate meter installed instead or alongside, this can be useful it the property could be dual purpose (think: duplex, house + machine shop, etc). This can increase costs because of double baseline but it can also reduce costs because of double "low tier" - depends on the market.
- signaturefish 4y agoI always forget the size difference between US and UK homes (I assume toomuchtodo is speaking from a US perspective). Here, in my three-bedroom UK house I'm on a 60A service fuse and considering updating to 100A in the future (amusingly, as part of a solar PV / electric vehicle charger install). I've never heard of a UK house having a larger than 100A service (although I imagine they exist here and there - it's certainly not common).
- SketchySeaBeast 4y agoI'd never heard of a 400 A service until just this discussion (it's common to have 100 A - 200 A), but it's important to keep in mind the voltage differences and that effect on total power: UK: 100 A x 230 V = 23,00 W US: 200 A x 120 V = 24,00 W Edit: I am wrong in my understanding of US power distribution. It's 200 A per leg, which the US has two of. But it seems like the UK may or may not have 380 3 Phase, so the numbers are weird there too. Wrong all around!
- throwawayacc3 4y agoVoltage to residential main electrical service panels in the United States is 240V. Major appliances run on 240V circuits. So when you install a 400A panel in the US, it's 400A*240V which is 96,000W.
- kuschku 4y agoAnd service in EU is 380V, so the relationship between the numbers remains similar.
- throwawayacc3 4y agoThat is incorrect. The EU/UK are on 230V at 50Hz at residential service entry.
- kuschku 4y ago
- danans 4y ago> if it's within your means, go to 400A to future proof (EVs, HVAC and hot water heat pumps, induction stove, and other large loads all add up, along with colocated generation of some sort I have all of these on 200A with amps to spare. But I have a small house. I suppose if I had multiple EVs, dryers, or heat pumps, or 3000sqft it would be a different story.
- rsync 4y agoAgain, see above - it's not about 400 amps per se ... it's about putting in bigger wire because we can't predict the future. It's spending a small additional amount now (on wire) to avoid an enormous expense (trench digging) in the future. Oh, and you know that 3" conduit required for the 400amp ? Make it 4". Oh, and you know that trench you just dug ? Throw in double 1.5" and double 3/4 conduits right in there with it. Oh and you know that first two feet of dirt you filled in ? Now throw two more 3/4 conduits on top of that because you never know when a common carrier on that same pole will have fiber up on it ... Future you will be very happy you did.
- danans 4y ago> Future you will be very happy you did. The future could also look like large batteries on-site that charge slowly, and then provide power at high amperage when needed, like slowly compressing a spring, then suddenly releasing it. This is already what Electrify America and Freewire (https://freewiretech.com/ https://freewiretech.com/) are doing with EV Fast chargers when the electric utility can't provide a higher power connection in a reasonable time-frame. As battery prices drop, that could be a viable way to power heavy home appliances.
- symfoniq 4y agoGood advice. I just did the 400 amp upgrade. Our 3200 sq ft house was still on 150 amp service from the 1980s, and going to 200 amps just didn’t seem to add much capacity relative to the cost. Was about $12K to go to 400 amps with two 200 amp panels.
- deleted 4y ago[deleted]
- londons_explore 4y agoThere are a lot of laws and regulations about electrical installations. In many regions, doing it legally requires lots of courses and certificates. When you have invested all the time and money into getting said certificates, which is sometimes multiple years full time, you typically want to become a full time electrician to pay back the time+money investment. That means that 'I just do electrics on the side' is becoming a thing of the past - at least in places with strict certification requirements.
- londons_explore 4y agoObviously in most parts of the world, there is no electrical police who will raid your home and look for evidence of wiring done without the correct certifications. Therefore, lots of people DIY stuff illegally... If you choose this route, understand that: * The main cause of injury/death caused by electrics is fires. Fires are normally caused by improper fuses (a fuse/breaker should always be the lowest rating of any device/cable/connector downstream of it, unless that device has its own fuse), or badly made joints. Do joints properly with wago blocks or by tightening screw terminals very tight. * The 'obvious' risk from electrics of electrocution is reduced to almost zero by installing a whole-house RCD/GFCI device. I wouldn't want to live in a house without one. And turn the power off before doing electrical work.
- actionfromafar 4y agoBut not too tight, or the strands may break.
- londons_explore 4y agoI have seen lots of near-fires/melted things from under-tightening, but I have never seen a single near-fire from overtightening. I suspect it's a myth - I don't think you could overtighten any connector sufficiently to make it be a fire risk without the screw shearing first. I'd be interested to see tests demonstrating otherwise though. Obviously if you are doing it to the standards, you crimp the wire first and use a torque screwdriver to tighten to the exact correct torque.
- elicash 4y agoThere's a startup that is adding a battery to induction appliances, in part so that you can run off of a standard outlet: https://www.channingcopper.com https://www.channingcopper.com It's only in pre-orders, however. Edit: Looks like first round of pre-orders were limited to Bay Area and now there's a wait list for next round.
- Siecje 4y agoYour comment implies that you could hook up a ordinary electric range but not an induction range. I thought induction used slightly less energy. Or is it that it uses more energy for a shorter time so the net is less but the peak is higher? I assume I could replace my electric stove with a stove with induction "burners".
- mankyd 4y agoI believe the answer is that induction is more efficient at getting heat into your food. With electric, it heats up a coil that heats up your pan (and the air around it) that heats your food. With induction, it skips the coil and simply heats the pan. The pans are specially designed to contain a heating coil in them which implicitly is closer to your food. It also means the work surface tends to cool quickly (or never get hot in the first place), making it safer.
- MarioMan 4y ago>The pans are specially designed to contain a heating coil in them which implicitly is closer to your food. Just to note, you don’t need special pans to use an inductive stove. Any magnetic cookware will do, which includes cast iron and most stainless steel. As an intuitive rule of thumb, if a magnet will stick to the bottom, then it’s compatible.
- mnw21cam 4y agoThe pan doesn't have a heating coil in it - it's just a solid slab of metal. However, that acts like a single turn of wire in a "coil" shorted out.
- greedo 4y agoInduction compatible cookware doesn't have a heating coil. They just need ferrous metal in them. They can be clad in aluminum, with a ferrous core etc. A cast iron pan works fine, and most stainless steel cookware is fine. It's just the cheap teflon stuff that's out of luck.
- 4y ago
- thehappypm 4y agoElectric water heaters don’t need to draw a ton of amps. 4500 Watt, 240V 50 gallon ones are common, which is under 20 amps. Induction stoves peak at twice that.
- danans 4y ago> my wife won't accept an ordinary electric range She's right. Induction has the speed and response of a gas cooktop with the precision a resistance electric cooktop. > and an electric water heater. Make sure it's a heat pump water heater if efficiency and operating cost matter to you.
- Al-Khwarizmi 4y ago> She's right. Induction has the speed and response of a gas cooktop with the precision a resistance electric cooktop. This, and also easier cleanability than either of them (basically it doesn't need more cleaning than the rest of your kitchen counter) and much safer (won't heat anything non-metallic that you leave on top, won't heat the surface of the stovetop itself except indirectly via heat transmission from the pots/pans, and will automatically turn off if it doesn't detect a metallic item). I have one and there's no way in hell I'd go back to an ordinary electric range as long as I can afford not to.
- bluGill 4y agoI've been looking at them, but almost all have unusable touch controls. (My background is human machine interaction - I've never seen an acceptable stove, but induction stoves are all really bad). Since I've have to replace all my cookware as well I'm not in any hurry.
- danans 4y agoFunctionally, the touch controls make the whole thing much easier to clean, but I agree they are harder to use. As with the touchscreens in cars, I'm sure it's also about marketing a sleeker product and lowering the bill of materials and labor - hence cost of manufacturing. Just wait a little longer and a manufacturer will start offering physical dials on an induction stove as a high-end feature, but also realize that it will still be control by wire like a computer input device, not a mechanically coupled control like a (dumb) dimmer switch - since it would be ultimately controlling the inductor in the stovetop via software.
- 4y ago
- bombcar 4y agoIt's interesting that I've found the people who are comfortable with plumbing are very wary of electrical, and vice-versa. Look for a "smart heat pump" water heater and you can probably get away without actually upgrading service unless you want to - 100 amp service can support a stove and water heater especially if the water heater is "smart" enough to not run when the stove is running. You can also find a friendly electrician to "check off" on your wiring after you do most of the grunt work, this works well for areas that require permits even for homeowner-done work.
- anon3846472 4y agoIn Taiwan, electricians and plumbers are the same occupation. When you're getting your certifications, you have to get both. You can specialize in one, but you have to know plumbing and electrical work to pass.
- bombcar 4y agoI was thinking more on the DIY side; I'm entirely comfortable with electrical, but I worry I wouldn't "do" plumbing right (soldering copper, mainly; I have no issue with PEX); a friend of mine is the opposite.
- latexr 4y ago> Of all the trades, electricity is the one that I know enough about to supervise somebody. (e.g. I am baffled by plumbing) Curiously, we’re in opposite situations. I have a (very) basic understanding of electricity, just enough to change power outlets and the like. But in general I’m baffled by it because it’s a bunch of dangerous stuff I can’t see with values I don’t fully understand¹. Plumbing, on the other hand, is water inside tubes controlled mechanically. Taking things apart reveals the simplicity of the system. After doing a fix I can feel confident in the safety and reliability of the work even before opening on the main valve again². ¹ If anyone has recommendations on a trustworthy course / YouTube playlist which teaches enough basics to understand electrical wiring in residential homes, I’m interested. ² I’m not doing super complex jobs, but in my own home it’s been years since I’ve needed to call a plumber.
- PaulHoule 4y agoI received a PhD in physics so I got a solid dose of electricity and electronics. I did help teach an autotutorial class in physics for premeds which got me to do a little more with fluid mechanics than most people but the trouble I have with plumbing is finding documentation for the details. For instance when it comes to sealing PVC pipes I have seen instructions that tell you to "refer to the documentation from the pipe manufacturer" which is not at all straightforward for pipes that have been there 20+ years.
- _whiteCaps_ 4y agoNot a course, but this channel has a ton of interesting content on US residential wiring: https://www.youtube.com/c/technologyconnections https://www.youtube.com/c/technologyconnections