The heat pump will be a 240VAC load. Consumer-level computer UPSes in the US are 120VAC. The 24VAC transformer for the control circuitry will be on one of the
by sokoloff 4y ago
The heat pump will be a 240VAC load. Consumer-level computer UPSes in the US are 120VAC.
The 24VAC transformer for the control circuitry will be on one of the 120VAC legs, but it's likely the installer didn't specifically wire it to allow partial powering of just the transformer and electronics board.
- jacquesm 4y agoHm... you might be able to get away with ordering a EU UPS then, those are 240V, you'll have to add a center tap transformer and maybe mess around a bit with it to get it to output 60 Hz (that will only improve efficiency).
- sokoloff 4y agoI think if you’re just looking to run the fossil fuel equipment from the UPS, you can do it by just ensuring that and all the transformers and controls are on that phase. That will take an HVAC person who knows who things work rather than just following colors on a wiring diagram. Probably easier and more supportable than trying to import and mod an out of region unit.
- jacquesm 4y agoProbably quite a bit more $ though. Anyway, I saw your message and figured it has to be solvable in a cheap and quick way, never mind me :)