I'd like to see an efficiency curve of this heat pump at -20F, 0F, +20F, +40F I have a heat pump that can be used for both cooling an heat along with a natural
by lizknope 4y ago
I'd like to see an efficiency curve of this heat pump at -20F, 0F, +20F, +40F
I have a heat pump that can be used for both cooling an heat along with a natural gas burner. The installer has set the system to use the heat pump at 40F and above and switch to natural gas at below 40F below based on the efficiency of the heat pump dropping at low temperature.
My heat pump is a SEER 18 unit primarily for cooling in the US south so I'm sure a heat pump designed specifically for northern cold climates will be more efficient than mine at low temps but I'd like to see how much.
- newZWhoDis 4y agoWell that installer cutoff was likely waaaaay too high. Your heat pump should be fine to 30F, maybe even 25F before needing gas. Modern systems are 24 SEER and good to -5, and these research units take that to the next level.
- Majromax 4y ago> Well that installer cutoff was likely waaaaay too high. Your heat pump should be fine to 30F, maybe even 25F before needing gas One possibility might be that the unit lacks de-icing circuitry. If that were cut for cost optimization, the unit would still work fine for cooling and for moderate-temperature heating, but anywhere near 30F it would ice up and stop working.
- bowow 4y agoUnfortunately only the very top-of-the-line (very expensive) variable speed compressor units are rated for anything close to 24 SEER / -5F (unless that's what you meant by modern systems).
- rudedogg 4y ago> Well that installer cutoff was likely waaaaay too high. Your heat pump should be fine to 30F, maybe even 25F before needing gas. The parent post was saying it's cheaper to use natural gas at those temps, so that's why the installer did the cutoff there. You can look at COP numbers for heat pumps here: https://ashp.neep.org/#!/product_list/ https://ashp.neep.org/#!/product_list/