4 ms·
This is brilliant, thanks. I do see how additional calculations between wet and dry (or just a hygrometer, which the Nest does have already) would be ideal, but
by hunter2_ 4y ago
This is brilliant, thanks. I do see how additional calculations between wet and dry (or just a hygrometer, which the Nest does have already) would be ideal, but as you say, using just a wet-bulb does seem a bit better than using just a dry-bulb in terms of approaching my goal, even if it's not quite all the way there.
Rigging a wet sock (with constant wicking from a water source) onto my actual wall-mounted Nest Thermostat would never fly, as I said, but I have no qualms about doing this experiment with my Nest Temperature Sensor, being a small and relatively cheap thing that I can easily steal for a while...
According to a psychrometric chart [0] it looks like if the dry-bulb temperature stays locked at 70F, while the RH drops from 60% to 40%, the wet-bulb temperature will drop from 62F to 56F. Or if the dry-bulb temperature stays locked at 80F while the RH drops as before, the wet-bulb temperature will drop from 70F to 64F. That's linear enough for my purposes.
Therefore if my conventional (dry-bulb) set point is 75F in the summer, and I'm most comfortable around 50% RH combined with that 75F, then I'll try a set point of 63F with my Nest using the remote Sensor wrapped in wet cloth!
Apparently I also need continuous airflow over this wet-bulb thermometer. I wonder how much.
[0] https://hvacologist.com/2022/02/21/wet-bulb-temperature-vs-dry-bulb-temperature/ https://hvacologist.com/2022/02/21/wet-bulb-temperature-vs-d...