3 ms·
In a previous life, I managed a team of instrumentation and tubing fitters at a new chemical plant that was being built. Some of the tubing for the process ana
by c_o_n_v_e_x 4y ago
In a previous life, I managed a team of instrumentation and tubing fitters at a new chemical plant that was being built. Some of the tubing for the process analyzers (chromatographs) had to be redone as they used PTFE tape on the fittings which was being detected by the GC.