3 ms·
> Gosh, I wonder where you guys live.. I'm on the west coast. Now in the Seattle area with A/C, and the air handler in the basement (which conditions the basem
by toast0 4y ago
> Gosh, I wonder where you guys live..
I'm on the west coast. Now in the Seattle area with A/C, and the air handler in the basement (which conditions the basement and the first floor) will form a fair amount of condensate where it's supposed to, but it can also form on the outside of the duct work too... Although the basement isn't super air sealed. So I'm just saying most of the condensation happens where it should, but not all of it. Of course, my basement isn't a machine room, either. I've only got a couple computers down there, and they're low power.
- StillBored 4y agoSo the basement is conditioned or not? Either way, residential AC duct looks like this: https://duckduckgo.com/?t=ffsb&q=ac+duct+r8+&ia=web https://duckduckgo.com/?t=ffsb&q=ac+duct+r8+&ia=web This stuff is run through attics and the like all over the southern US where the attics are at ambient humidity levels, and I can't remember the last time I saw condensate forming on one that was properly sealed with mastic. In fact it would probably be a problem if it was because it would be dripping through the attics into the drywall ceilings. R8 doesn't sound like much, but its apparently enough to keep the outside of the duct from feeling cool at all.
- toast0 4y agoBasement is conditioned, and the air handler and the duct with condensation are in the conditioned space. Most of the duct work is out of sight so I can't say if it's got insulation, but right by the air handler, it's just sheet metal, no insulation. It's not properly designed, or built... but it's there. Mostly it works ok, just gotta have a separate dehumidifier near the air handler to keep things under control... fixing the zoning helped a bit too.