2 ms·
Check the datasheet for the fridge compressor. Some models are designed to run in two orientations. If you're very lucky, the other orientation for your com
by londons_explore 4y ago
Check the datasheet for the fridge compressor. Some models are designed to run in two orientations. If you're very lucky, the other orientation for your compressor will be 'on its back'.
If you run the compressor in an orientation it isn't designed for, the motor will get 'liquid slugging', which is unrecoverable - you'll need to buy a new fridge.
- londons_explore 4y agoBy the way, if liquid slugging is caught before the motor burns out (some motors have an overload disconnect), then you can normally switch around the start capacitor onto the run wiring and vice versa to run the motor backwards. Running it backwards for a second can release the liquid and 'fix' the fridge.