It was up around 250 Bq/m^3 at its peak, and then I cracked open the two basement windows and it has since dropped to around 110 Bq/m^3. In Canada the recommend
by voisin 4y ago
It was up around 250 Bq/m^3 at its peak, and then I cracked open the two basement windows and it has since dropped to around 110 Bq/m^3. In Canada the recommendations are to deal with it ASAP if over 200, and to deal with it within the next 2 years if it is 100-200.
I’ve looked and don’t see any cracks in the slab, but admittedly 1/2 of the basement is carpeted and drywalled and so I don’t have a good view of it.
I use the AirThings View Plus, and note that it has been running for 2.5 months, and I want to see what it settles at as a longer term average.
- deleted 4y ago[deleted]
- myself248 4y ago> 1/2 of the basement is carpeted and drywalled Realistically, popping a hole in the slab and installing a fan might be less disruptive than tearing out all the finishing. Do you have a sump? First, seal it. Caulk as much of the wall-floor joint as you can. If it's still not low enough, add a fan _to the sump cover_, since the weep-tile system might provide all the sub-slab vapor communication you need without adding any new holes.
- deskamess 4y agoCan radon come in through the walls? We recently got a crack in the basement wall and a small water leak. Will be fixing the leak next spring, but I am curious if this is a cause for higher readings. The long term average is about 135 but it occasionally spikes to 200+. Also in Canada.
- myself248 4y agoTechnically yes. It's a gas, so it'll permeate through anything that's gas-permeable. And being a noble gas, it's pretty small, not as small as Helium, but still it'll wander right through membranes that're gas-tight for diatomic molecules and larger compounds. However, that is almost always a rounding-error in terms of basement soil-gas infiltration. You can sometimes feel a literal breeze coming through a crack if the house is badly depressurized (windy day and stack-effect), you will never feel a breeze coming straight through a solid concrete or cinder-block wall. The spikes probably come from depressurization events like that. Sometimes the wind is angled in such a way that the house effectively forms a whistle or a manometer, and soil gas migrates at a greater rate during those times. This is somewhere that _passive_ sub-slab ventilation (drill a hole, connect a vent pipe to the outside, no fan) can often help significantly, along with caulking all the cracks. Seriously, don't bother with anything else until you've caulked.