4 ms·
(Am I missing a joke?) He's talking about 5-over-1 or one-plus-five buildings. They're 6 story midrise buildings that have 5 stories made of wood on-top of on
by MichaelCollins 4y ago
(Am I missing a joke?)
He's talking about 5-over-1 or one-plus-five buildings. They're 6 story midrise buildings that have 5 stories made of wood on-top of one made of concrete. They're extremely common in North America, and they aren't firetraps because they have sprinkler systems, redundant emergency staircases, building wide fire alarms.
- bombcar 4y agoThey ARE firetraps when being built of course. But once finished they’re pretty normal. A concrete building doesn’t protect you from fire as much as people might think.
- ars 4y agoWhy is the bottom one made of concrete? (i.e. and not just the foundation)
- coryrc 4y agoResidential requires a higher level of fire safety than commercial and additional separation between uses for occupant comfort (f.ex. sound). Additionally, there is usually parking and that also requires a lot of separation.
- tremon 4y agoSo it's not just different building materials, it's also mixed-use zoning? 1 level of commercial space + N levels of living space above it?
- coryrc 4y agoNo, see https://en.wikipedia.org/wiki/5-over-1 https://en.wikipedia.org/wiki/5-over-1 "5" and "1" are not the number of floors, they are the construction type, 5 being (primarily) built of dimensional lumber and drywall, 1 being reinforced concrete. The type for heavy timber is "4". This, a building with CLT would never be 5-over-1. It might be 4-over-1, but I bet it's sufficiently inherently fire-resistant that most designs will be solely type 4.
- MichaelCollins 4y ago> No, see https://en.wikipedia.org/wiki/5-over-1 https://en.wikipedia.org/wiki/5-over-1 No, see https://en.wikipedia.org/wiki/5-over-1 https://en.wikipedia.org/wiki/5-over-1 > The name derives from the maximum permissible five floors of combustible construction (Type III or Type V) over a fire-resistive Type I podium of one floor for "5-over-1" or two floors for "5-over-2", as defined in the United States-based International Building Code (IBC) Section 510.2. > Some sources instead attribute the name to the wood framing of the upper construction; the International Building Code uses "Type V" to refer to non-fireproof structures, including those framed with dimensional lumber.[5][6] First sentence affirms my comment, second sentence affirms yours. I suspect the second usage is primarily European, or just mistaken. In America, 5-over-1 refers to the number of floors. Particularly, the upper five might be Type III not Type V, but it's still called a 5-over-1. And if there are two bottom Type I floors, it's called a 5-over-2.