Typical heatpump COP in Northwestern Europe sits at about 4, that means for 1 kWh of electricity your moving 4 kWh heat into your home. Electrical resistive hea
by brnt 4y ago
Typical heatpump COP in Northwestern Europe sits at about 4, that means for 1 kWh of electricity your moving 4 kWh heat into your home. Electrical resistive heating sits at 1:1 by definition, and methods like wood, gas or oil, combustive methods, usually with modern installations at 80-95% efficiency. Further south heatpump COP improves; the rule of thumb is a smaller delta T the better.
Moving heat is always more efficient than creating heat. It's elementary physics.
Airconditioners, or air-to-air heatpumps, are cheap heaters for the same reason (any units sold in the last 10 years can move heat bidirectionally). Here in NW Europe by cooling bill is barely noticeable (it's no desert clime after all, although the last decade seems like it's getting there!). You don't need to set it to 18C; I really only cool when the attic gets over 28C while I work there (home office), down to 24-26, which is a few weeks a year. In winter, it heats the room at ~400% efficiency compared to the typical ~80 for gas heating.
Move heat. Don't create it.
- redeeman 4y ago> Typical heatpump COP in Northwestern Europe sits at about 4 :) yeah, when its really quite warm outside, but not quite warm enough that you dont need heating. as soon as you even get down to 5C outside, you are not getting a COP of 4. Many vendors may tell you that, but well... :) some people were also sold bridges :)
- brnt 4y agoA lot of people in my environment are in fact getting sCOP of 4. Bit better in fact: close to 5 in the group that also installed floor heating everywhere. Note that COP around freezing is almost always the worst due to frequent defrosting, so yes, COP is worse at -5 most likely. You can replace COP with sCOP in earlier replies of mine. What is true is that most people, including installers, don't know how to tune them very well, or forget to combine them with low temp radiators/ floor heating. Too high a T_out also occurs frequently. In the Netherlands, heatpumps have been standard issue in new construction for a decade now, and 4 is about the average. It's very much not imaginary, but hard to believe for people from areas used to wood and oil burning ;)
- redeeman 4y agoi would question whether that is in fact happening. MAYBE scop, for the recent winters where it has not been cold, but unless you have a vastly overdimensioned setup for what is done now then, you'll be screwed if a real winter happens again
- brnt 4y agoOverdimensioned: that can be a cause for low COP, and not always a surefire solution. But yes, properly dimensioning to your particular situation is more important than with other heating methods, agree. The best point I think is to target not the coldest winter you'd ever expect, because that means suboptimal runtime the rest of the year. Better is to target optimal runtime for most of the year, and accept horrible performance for a few days every 5 years or so. Modern heatpumps work perfectly fine down to -20C or so, which covers nearly all of Europe. If your winters are around 0C, it really pays to get units with better defrost management. You can use power output ratings; cheaper brands might have a third less output at 0deg, while others barely dip. In colder countries the cheaper units are funnily enough a great option, because once it's cold enough to continuously flow, you don't have to defrost at that often anymore.
- redeeman 4y agothey might work at -20C, but you cannot get ANYWHERE near the output out of them as you can when its hotter. Several of my family members have heatpumps, myself included, and I can tell you that the COP reduces significantly as soon as we hit just 0C outside. my panasonic has a supposed SCOP of 5.1(or 5.2, cant recall), when it hits 0C here, its down to COP of ~2.5 at my best estimates. when it hits -10, the COP is at best 2. I know this because I think around 1300W into it, and it is not able to heat my house more than a 2.5kW resistive heater. this is their 3 year old flagship "nordic heat pump" that they will market as the sole heating solution for houses twice the size of mine, yet can barely do mine when it hits -5-10C :) edit: im not saying heatpumps are bad, they are great, but I dont think they are a great ONLY solution for places that are below 0C for more than tiny peak times. when its 5-10C outside, and you want 22C inside, they are really amazing