4 ms·
I worked in a lab where we invented basically the same scheme in about the same time. I still have a box full of those little grey plastic RJ-45 to DB-9/15/25 M
by fargle 4y ago
I worked in a lab where we invented basically the same scheme in about the same time. I still have a box full of those little grey plastic RJ-45 to DB-9/15/25 M and F adapters.
The cable plant improvement was good - we could punch down CAT-3 (later CAT-5) into keystone jacks and patch panels without regard for whether it was RS-232 or RS-422/485. The big advantage is that you only have one type of wiring and that it's flexible as to whether it was 10Base-T (later 100) or serial.
I used a different pinout that worked well for us:
1. almost all of our systems were 3-wire (no hardware handshake, just RX/TX/GND). In a few cases we needed extra signals and then used the other two pairs.
2. we treated each RS-232 as a pair of GND/signal. Put Rx/GND on 1/2. Tx/GND on 3/6. this provided a little better "shielding" because the ground wire was twisted around the signal wire vs. having TX/RX twisted with each other.
2a. In RS-422/485, used the same pairs but RX+/RX- on 1/2 and TX+/TX- on 3/6 with a chassis ground on one other pin.
3. By using 1/2 and 3/6 it made standard Ethernet cables "straight-through" and made Ethernet cross-over cables into null modems. I wired terminal servers and workstation adapters "backward" (not unlike Ethernet switches vs. hosts or DCE/DTE). This made for very few crossovers required.