LTO is referring to refurbishment efforts to extend the lifespan of an existing plant. Look at the first line in that chart. It's for 20 years of operation of
by pfdietz 4y ago
LTO is referring to refurbishment efforts to extend the lifespan of an existing plant.
Look at the first line in that chart. It's for 20 years of operation of a 1000 MW reactor. The capital cost is listed as $5.93/MWh. If that reactor is operating at 90% capacity factor for 20 years, the total capital cost comes in at less than $1B. That cannot possibly be the cost of building a new nuclear plant. Instead, it's the capital cost of the refurbishment needed to allow an existing reactor to operate for another 20 years. This can surely be a nice way to get more from many existing NPPs (although some of these refurbishment efforts have gone disastrously wrong; see Crystal River 3 in Florida for example), but it has little relevance to the cost of building a new NPP.
- ETH_start 4y agoYes, you're correct. Your interpretation is the only one where the numbers make sense.