I'm a huge fan of wondering openly whether what people commonly do is best, or if it's just best for some people and everyone else does it because they haven't
by johnklos 4y ago
I'm a huge fan of wondering openly whether what people commonly do is best, or if it's just best for some people and everyone else does it because they haven't really thought about it.
For instance, the idea that an expensive, thousand plus dollar rackmount server is only able to run in a special place where the temperature is just right and might fail if a fan fails or the temperature is a wee bit higher than usual is utter bollocks.
I build my own rackmount servers that can run at 100º temperatures, even with fan failures. I know this because that's how I test them. I have the OS aggressively throttle on the most egregious failures, but fan failure is much less common in general when you're using 80mm Noctua fans instead of 40mm fans that have to run at many thousands of RPM to keep their zones cool.
So maybe people need to rethink the idea that datacenters have to be kept at 70º or below, and instead should insist on better thought out hardware.
- pclmulqdq 4y agoGoogle datacenters run hot, as do many other cloud providers. They are happy to use high temperatures in their DCs to improve efficiency. The problem is that they have also removed the equipment to handle super-hot days for "efficiency."
- knorker 4y agoYour servers can run at 100℃ ambient temperature? Oh, I guess you mean F? Yeah, servers can run just fine at 40℃. Well… unless they fail because of it. :-) That is: The ones that don't fail work just fine. If you have a DC with 10'000 of your servers, and maybe 30'000 hard drives. What percentage of them will fail on any given day at 25℃ vs 40℃? But it's not just your servers. Can your AC equipment/evaporators work at 40℃? And if your ACs start failing you could be looking at a cascading failure where it's actually more like 60-70℃, or just plain "a fire", in your DC. Can your generators work? And the answer also isn't "every component in my DC must be milspec extended temperature range". It's actually fine to build a DC in Iceland that's not specced for outside temperature of 50℃. In fact it would be a ridiculous waste to do so. Google of course measures this. E.g. https://www.techrepublic.com/article/google-research-temperature-not-a-major-factor-in-hard-disk-failures/ https://www.techrepublic.com/article/google-research-tempera... But do keep in mind that 40℃ outside may mean 50℃ inside. Or indeed just 60℃ hotspots on the DC floor. Hell, your network cables may not even be rated for 60℃. They usually aren't. Your server may be fine with 40℃ inlet, but going out the air may disconnect it due to melting the network cable.