3 ms·
It's possible. NREL's ENDURING system does just that. https://arpa-e.energy.gov/sites/default/files/2021-03/07%20Day1-Zhiwen%20Ma_NREL.pdf https://arpa-e.ener
by pfdietz 4y ago
It's possible. NREL's ENDURING system does just that.
https://arpa-e.energy.gov/sites/default/files/2021-03/07%20Day1-Zhiwen%20Ma_NREL.pdf https://arpa-e.energy.gov/sites/default/files/2021-03/07%20D...
Quick stats: stores heat in sand at 1200 C, round trip power->power efficiency of 54%, LCOS of $0.05/kWh for 100 hour storage. Heat is transferred from the sand to the gas for a Brayton cycle by direct contact in a fluidized bed heat exchanger. Babcock and Wilcox is expanding this now to the pilot stage under an exclusive license.
- mikewarot 4y agoThat is a very elegant work around. {They never convey the particles while hot, only after they've given up their heat, or before they get heated and then fall into hot storage} I'd be happy with 54% round trip efficiency, it's way better than losing renewable power by not being able to store it.