4 ms·
Funny enough the compressor on the older heat pump that came w/ my house blew this week after a power surge. Got to watch a smokey mist of R-22 leak for a sever
by Glyptodon 4y ago
Funny enough the compressor on the older heat pump that came w/ my house blew this week after a power surge. Got to watch a smokey mist of R-22 leak for a several hours.
I knew the unit was into EoL based on age, but when something seems to work fine it's really hard feel like preemptive replacement is the right choice or priority.
At least in the US R-22 is so expensive and people still repair and recharge units not infrequently. Wonder how reasonable or possible capturing leaking refrigerant would be. I was watching it leak and vaguely wondered if it would be possible to catch in a large umbrella.
- lazide 4y agoNormally the tech would recapture it, and it is worth something. It must have been a pretty dramatic failure for the coolant to leak from a power surge. That said, ‘reduce, reuse’ comes before ‘recycle’ for a reason. If the unit still worked and was reasonably close efficiency wise, it’s just a waste to replace it when it still functions.
- StillBored 4y agoIt probably caused the power surge. What he describes is a fairly common failure mode. The compressors are hermetically sealed, and the weak point is where the AC is plugged into the compressor casing. As they age they corrode once the plug loses its own environmental seal driving up the capacitance of the junction, or the compressor starts to draw increasing amounts of current to start and run, resulting in the plugs melting. Basically its any number of effects, but the result is that the plug shorts/melts/etc and the compressor loses its seal at the same time. Generally this kind of failure was a couple hundred dollar fix. Pull the compressor, braze on a new one, flush the system, vacuum it down, and refill. Only now, the refrigerant can cost a grand, the markup on a $200 Emerson scroll is 4x, the fact that you need a license to work on the system means the tech charges $200 an hour, and it all adds up toe selling someone a new system, that is likely going to last 1/2 as long because R410 runs at 2-3x the pressure, the major manufactures have penny pinched every gram of metal out of the condenser/compressor tubing so its as thin as possible, and a half dozen other factors means that the 30 years a good R22 system would run for is unheard of now.
- Glyptodon 4y agoSounds about right to me, only r-22 refrigerant alone would have been more than two grand $ on its own, let alone labor, parts, or other services. (And prices they quoted per lb were in line with other HVAC places in town.) Definitely the cost of replacement coolant was a big driver of how things played out (in concert with system age).
- drewzero1 4y agoEdit: Got mixed up with R-12, which was used in cars and apparently runs at a lower pressure. I looked into an R134a conversion for my 1990 car about 10 years ago and found that any remaining R-12 would need to be vacuumed out of the system and collected for re-use. I elected to just live without A/C for a few more years and let the junkyard collect the refrigerant when I ended up scrapping the car.