4 ms·
I have one even better, just to show how you can't be sure... Replacing an outlet. Shut off the 2-pole breaker for the shared-neutral circuit it was on. Outlet
by masterbee 4y ago
I have one even better, just to show how you can't be sure...
Replacing an outlet. Shut off the 2-pole breaker for the shared-neutral circuit it was on. Outlet tester showed the outlet was off. Pull the receptacle out. Used a multimeter to test each wire contact to ground; all were 0v.
Only when I disconnected all the wires did one of them develop potential because somebody had apparently tied a neutral wire to a hot in another box, but I still don't understand the situation and had an electrician address it.
So even testing each individual wire isn't certain unless they're all hanging free, unless you make the assumption that things were wired correctly in the first place.
- scotty79 4y agoWhen I'm working with home circuits I use indicator screwdriver all the time and I'm touching everyting metal with it at every step of the way. I'm very rarely surprised with what happens but it still happens occasionally. For example today I was surprised when RCD tripped when I shorted ground and neutral on a circuit that was disconnected by its own breaker. I had to think for a brief moment to understand that yeah, it's perfectly reasonable that this happened and no, I'm not in any danger.