3 ms·
Was the 'older model' in this case one of the models where it is known that manufacturers were shipping SMR drives without disclosing it?
by sithadmin 4y ago
Was the 'older model' in this case one of the models where it is known that manufacturers were shipping SMR drives without disclosing it?
- antongribok 4y agoNo. Both models were PMR. I tried to find out more about what the differences are from the manufacturer, but didn't get far. Perhaps someone here can shed some light. Older drive: model number: MB8000GFECR SATA Version: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) ATA Version: ACS-3 T13/2161-D revision 5 Newer drive: model number: MB008000GWWQU SATA Version: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s) ATA Version: ACS-4 My guess at the time was that the newer drive had a deeper command queue, but I'm not actually sure, and I think both drives had the same amount of cache.
- deleted 4y ago[deleted]
- sithadmin 4y agoI'm not seeing any especially obvious differences between those models (aside from the ones you listed). Were the drive versions mixed in alongside each other behind the same storage controller? If so, I would wonder if perhaps the controller's handling of different SATA versions played a role.
- antongribok 4y agoIt's possible. Yes, the drives were sprinkled around in the inventory, and we had some servers where there was a mix of old and new drives in the same box, behind the same controller. We use the controller in HBA mode, so the controller shouldn't be doing anything fancy, but you might be right.
- sithadmin 4y agoI've seen controllers in HBA mode pull some oddball performance shenanigans when presented with differences as small as running different drive firmware versions across connected disks, so it really wouldn't surprise me. SATA drives have a pretty bad reputation for firmware releases introducing unexpected and undocumented behaviors. I used to be on the customer success team for a hyperconverged distributed storage product, and such things were the bane of our existence. Over the years the inventory of product-supported SATA devices shrunk considerably as a.) more and more quirks were discovered in products and b.) flash prices continued to drop to the point that spinning disks were in less and less demand, putting downward pricing pressure on SAS devices.
- justinclift 4y agoThose model numbers seem to be the HP part numbers. Don't HP rebadge drives from other vendors? If so, then it would probably be useful to see if the vendor drive model numbers are available. For the dramatic increase in iops, I wonder if there are more head+actuator assemblies on the newer drives or similar? Along the lines of these: https://www.seagate.com/innovation/multi-actuator-hard-drives/ https://www.seagate.com/innovation/multi-actuator-hard-drive...
- antongribok 4y agoThese are both Seagate Exos drives, one is a generation newer than the other. I'm pretty sure both have the same number of platters, thus same number of heads. And yes, HP changes the firmware and model numbers... super annoying.
- rasz 4y ago> had an agreement >We got the vendor to send us new drives and shipped the older model back to them not much of an agreement then, shows where the power lies >MB8000GFECR Seagate ST8000NM0055 at 2-4x the price >MB008000GWWQU another seagate