3 ms·
If there's a plunger resisting the scale going down to harvest energy, that would prevent all the force from being on the load cell, giving you incorrect readin
by BenjiWiebe 4y ago
If there's a plunger resisting the scale going down to harvest energy, that would prevent all the force from being on the load cell, giving you incorrect readings.
- hundchenkatze 4y agoCouldn't you subtract the resistance of the plunger and display the adjusted value?
- shkkmo 4y agoNot if the plunger rests on the load cell. Then plunger just captures the work done as it is compressed, it doesn't reduce the force that passes through it (once at equilibrium.)
- ars 4y agoYou can put the switch in between the plate and the force sensor. Then all the force is on the sensor and is also a switch.