The Twitter thread links to this study: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909253/ https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909253/ Which find
by Imnimo 5y ago
The Twitter thread links to this study:
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909253/ https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909253/
Which finds that fume hoods do not help:
>NO2 concentrations in the kitchen and bedroom did not significantly change following ventilation hood installation.
These are outdoor vented:
>Ventilation hood: Range hoods [BROAN® (Hartford, WI, USA) Range Hood model numbers 433611, 403001, or 423001] with ventilation fans to the outdoors and secure seal to minimize energy loss were installed over existing gas stoves.
- nobodyofnote 5y agoI keep seeing this study referenced. However, I find it pretty glaring that the Range Hoods they used are not even adequately rated for gas stove usage. For instance, they listed "flow rates for the models used as 160–220 cubic feet per minute". These are range hoods typically used for electric models - not gas. 400 CFM is generally considered a baseline hood for gas stoves (100 CFM / 10000 BTU). I would feel much more confident in their results had they used more powerful range hoods that were more appropriate for the stoves in question.
- aidenn0 5y agoI've never had a kitchen with a 400CFM+ range hood, despite 50-50 gas appliances. All but one have been micro-hood combos and those don't move much air at all.