they are a stack of elements that are connected every X height that has a well known flex per connection. It's also (hopefully) a uniform flex at every connecti
by Animats 5y ago
they are a stack of elements that are connected every X height that has a well known flex per connection. It's also (hopefully) a uniform flex at every connection.
The flex is supposed to be in the beams, not the connections. Stress concentration is bad. Here's an intro.[1] Beams are easy to analyze, and tend to meet their specs, while connections are hard to analyze, and are subject to construction mistakes.
The January 1994 Northridge CA earthquake caused damage at beam-to-column connections in steel moment resisting frames. That got a lot of attention. Few buildings collapsed, but a lot of joints needed to be fixed or reinforced.[2] Welded flanges with bolts turned out to be weaker than expected.
Now, there's a style of construction where all the joints are rotational. That's seen in older truss bridges.[3] In classic designs, all components are in pure compression or pure tension. This shows in the construction; the tension components are flat plates or cables, and the joints are big steel pins. Those are easy to analyze, and if you take a statics class, that's a homework assignment. Popular for railroad bridges.
But building skeletons aren't usually built that way. They usually have rigid connections. You do see some buildings with lots of diagonals and pin joints. Long span roof trusses, which are a lot like bridges, are often built that way. Look at buildings with large atriums and you'll often see pin joints.
[1] https://www.thestructuralmadness.com/2014/04/possible-types-of-failures-in-steel.html https://www.thestructuralmadness.com/2014/04/possible-types-...
[2] https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nistir5625.pdf https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nistir5625.pdf
[3] https://en.wikipedia.org/wiki/Truss_bridge https://en.wikipedia.org/wiki/Truss_bridge
- jacquesm 5y agoSame with long low steel buildings, they usually have a lot of room for expansion built into them because the tops are close enough to the foundation that the angle of the uprights would change a lot if not dealt with in such a way. For higher buildings this isn't as much of a problem because the parts closer to the foundation will likely be closer to ambient. In one particular case (the steel truss roof of a convention center in Amsterdam) there are many such places where slack was built into it, the structure is many 100's of meters wide and if connected rigidly would put undue stress on the uprights and the foundations.