The earth leakage protection applies to the whole system. > no way to disconnect if you happened to grip it the wrong way This is what the explosive breakers
by londons_explore 5y ago
The earth leakage protection applies to the whole system.
> no way to disconnect if you happened to grip it the wrong way
This is what the explosive breakers are for.
Here is an article with more details:
https://www.vehicleservicepros.com/service-repair/battery-and-electrical/article/21186567/hybrid-and-electric-vehicle-high-voltage-isolation-fault-systems https://www.vehicleservicepros.com/service-repair/battery-an...
Note that it appears there are a few hybrid cars made in the 90's without this protection!
- jacquesm 5y agoThis is only about chassis ground current, not earth leakage, which is strictly the domain of the charging circuitry. Seriously: if you do not understand the difference please do no not start messing with the HV side of an electric vehicle. Below 48 V is considered a safe voltage but can already - under the right conditions - cause you plenty of hardship and I'm aware of one death from a 48 V system. Anything higher than that with voltages between 200 and 600V pretty much the nastiest range because it is too low to arc and high enough to kill you needs special precautions, tools and ways of working to keep you safe. You can't rely on technical measures to keep you safe when diagnosing and repairing those circuits because those technical measures could be the cause of the fault.
- tragictrash 5y agoThe explosive Breakers would not help you in this case. Those Breakers likely blow in hundreds of amps range, you only need one 100th of an amp to stop your heart.