3 ms·
I don't think there are really any major risks to human life from the high voltage under the hood of an EV. The electrical system checks for earth leakage faul
by londons_explore 5y ago
I don't think there are really any major risks to human life from the high voltage under the hood of an EV.
The electrical system checks for earth leakage faults all the time, and will switch off if it finds one. That means a baby can chew any of the big scary orange wires and still survive.
The only real dangerous bit of an EV is the battery pack - if you cut it open.
- jacquesm 5y agoIn your case it appears that Mercedes made the right decision. 400 V DC with for all practical purposes an internal resistance so low that it might as well be zero is about as nasty as it gets. Zero warning until you touch that live terminal and then no way to disconnect if you happened to grip it the wrong way, and when you short it out you're going to be in for a world of hurt. The earth leakage protection only applies to the charging circuitry primary. So, even if I don't agree with the principle it looks like for some users this actually applies, which I find somewhat surprising.
- londons_explore 5y agoThe earth leakage protection applies to the whole system. > no way to disconnect if you happened to grip it the wrong way This is what the explosive breakers are for. Here is an article with more details: https://www.vehicleservicepros.com/service-repair/battery-and-electrical/article/21186567/hybrid-and-electric-vehicle-high-voltage-isolation-fault-systems https://www.vehicleservicepros.com/service-repair/battery-an... Note that it appears there are a few hybrid cars made in the 90's without this protection!
- jacquesm 5y agoThis is only about chassis ground current, not earth leakage, which is strictly the domain of the charging circuitry. Seriously: if you do not understand the difference please do no not start messing with the HV side of an electric vehicle. Below 48 V is considered a safe voltage but can already - under the right conditions - cause you plenty of hardship and I'm aware of one death from a 48 V system. Anything higher than that with voltages between 200 and 600V pretty much the nastiest range because it is too low to arc and high enough to kill you needs special precautions, tools and ways of working to keep you safe. You can't rely on technical measures to keep you safe when diagnosing and repairing those circuits because those technical measures could be the cause of the fault.
- tragictrash 5y agoThe explosive Breakers would not help you in this case. Those Breakers likely blow in hundreds of amps range, you only need one 100th of an amp to stop your heart.
- tragictrash 5y agoDon't worry buddy we'll do everything we can to get those enhanced warning messages out there so you can be safe too.