I was going to post about code violations but I’ll just tuck it under yours here so we don’t flood the top level (although one could argue that this really dese
by hinkley 5y ago
I was going to post about code violations but I’ll just tuck it under yours here so we don’t flood the top level (although one could argue that this really deserves it).
I had to stop reading r/diy because half the stuff in there made me angry. Especially people building lofts to store heavy stuff without knowing anything about construction.
You can’t overlap rooflines like this. That’s how they allow people to build small outbuildings but make large projects have to get permits. If the roofs “touch” then you’re using a loophole to make an illegal addition to your house instead of a shed.
> The way I did it was to run both wires inside a 3/4 inch PVC conduit using 14/2 electrical wiring + 100ft cat6 ethernet cable.
You are going to get somebody killed. I didn’t see you dig a trench, which means you have a single plastic conduit carrying power and data and exposed to the air. It’s supposed to be grounded metal buried conduit to create a faraday cage that can’t be electrified by nearby lightning strikes or hit by a tree or debris in a wind storm. And deep enough the next owner doesn’t kill themselves planting a hydrangea.
I have half a mind to doxx you to your city planning office.
- R0b0t1 5y agoYou don't need to take power underground. Most midwestern construction doesn't and I usually see PVC conduit. There are hazards from breakage, but putting it in PVC conduit tends to exceed code.
- jacquesm 5y agoPutting signalling and power wires in the same conduit is about as bad as it gets. The proper way to do this is to dig a trench and use armored cable suitable for burial without further protection and to use a plastic uninterrupted tube for the cat6 (which you can blow through). That said, there isn't a lot of difference between a DIY person and a low grade contractor, and a competent DIY'er is probably better than most mid level contractors. The big difference is usually that they have the tools and they're with a couple of people and you're just by your lonesome.
- raytube 5y agoJust expose the armoured cable. Hardly an issue, and you know where it is.
- jacquesm 5y agoNot a good idea. The outer layer is plastic, underneath that something that is best described as an oversized shower hose. Burying it will allow you to take vehicles, wheel barrows, lawnmowers etc over it without damaging it. I bought a ton of this stuff surplus from a dam construction, that served me quite well in Canada, some of the outbuildings were quite far away from the main house. It's pretty easy to work with, though stripping it is a bit of an art (you really don't want to damage the inner wires).
- 0xbadcafebee 5y agoThe author's shed is about 2 feet from the house exterior, so he can wrap the steps around as decking (very tiny decking) and put the cable under the steps.
- kevin_thibedeau 5y agoThen one day someone cuts up that decking with a sawzall and gets an unexpected surprise.
- jacquesm 5y agoThat's possible, but you'd need to clearly mark it. For two feet it's overkill, but normally, especially if there is the possibility of going between the two structures, you'd dig down 4', lay down your cable so that it is going down vertically in both structures and is well below the frost line where you bury it horizontally.
- ErrantX 5y agoYou can get armoured cable specifically with UV rating for this. I'd only ever run it against a wall etc. But it is designed to be above ground.
- stickfigure 5y agoIt's short. Put a normal extension cord in the "conduit", with plugs on each end. At least here in California, electrical code ends at the receptacle. You can do practically anything you want on the other side, as long as it plugs in.
- sgtnoodle 5y agoI'm pretty sure it's against code in CA to install an extension cord permanently inside a structure or conduit like that. When I put all the cables in the wall for my TV, I ran Romex from the bottom junction box to the top junction box, despite the bottom junction box having a male electrical plug. An extension cord plugs into that from another outlet. (Ideally I would have just hardwired the upper outlet, but that would have been another can of worms.)
- jacquesm 5y agoThat trick won't work. An extension cord is only seen as such as long as it is not permanently attached to a structure, and definitely not when it powers a fixed structure. In other words, it needs to be temporary and to be disconnected when not in use. As soon as you connect it permanently affix it or bury it you are violating the electrical code. Otherwise this would act as a giant loophole around the electrical code, you could simply use a high current plug to connect your distribution panel and call it a day. https://plasticinehouse.com/can-i-use-an-extension-cord-to-power-my-shed/ https://plasticinehouse.com/can-i-use-an-extension-cord-to-p...
- stickfigure 5y ago> Otherwise this would act as a giant loophole around the electrical code ...it basically is? People use it that way. All the time. Whether or not you like like that, it's the way it is. Personally I'm pretty ok with it. This guy is not actually going to kill someone with his shed.
- tharkun__ 5y agoI like your parent's explanation of why screws are not allowed by code in some places and also saying that yes, screws actually can be used, if you use the right ones, even if they aren't allowed by code in some places. I really like that because just mentioning code doesn't do any good. Just because code says something doesn't mean that it makes sense. There's tons of omissions in codes or stuff that is unnecessarily restrictive or way not enough to be safe. Screws are the perfect example. If code forbids screws but you are going to use the proper screws that are (with good reason) allowed in other jurisdictions that has a completely different vibe to it than someone blogging about using dry wall screws to frame a house. One is a safety concern and why inspections are a good thing, while another is a minor case of ignoring code without any concerns and where an inspection would suck (if you were the homeowner doing some work yourself). If they want to use something that is more expensive and let's them do something themselves that they wouldn't be able to do at all if they had to use nails, more power to them! Change code to allow the right type of screws! Your second part of the reply does the same, it sort of explains why you think it's a bad idea (and I agree that it is for various reasons). Could you explain why it is not a good idea to overlap roof lines?
- hinkley 5y agoOverlapping rooflines allow you to make a “detached” building that is functionally an addition to your house. The downside is that if you want to build a breezeway to a detached garage you’re going to have to get permits to do that. It sucks but otherwise you get people who make a long narrow house that’s a series of rooms that were built over time, and never inspected. You may see properties that have three fairly large but separate buildings, this is often someone skirting building codes in such a way that they stay within the letter of the law.
- hamburglar 5y agoThis still doesn’t explain why overlapping rooflines are actually problematic, though. I have always wondered this myself, as I actually own a house with a detached garage where the previous owner and next door neighbor put an easement on file that allowed the next door neighbor (whose ground level is about 5 feet higher via a retaining wall) to build an outbuilding very close to the property line with the roofline hanging over my garage by about 6 inches. So far, the only practical downside is that my downspout ends up getting all the water from half of his roof, which means the problem is worse if I don’t keep it clear. Not a terribly big problem in my book, since I have to keep it clear anyway. What else am I missing? (Note: there are other things that are suboptimal about my garage, namely that it was built 100 years ago right on the property line and when it was rebuilt sometime later, it was allowed to stay there despite normally having a 5 foot setback requirement. As a result, this concrete block structure itself actually serves as part of the retaining wall and has moisture seepage issues from the uphill side. I actually think having the neighbor’s outbuilding covering that patch of land and managing the rainwater via my downspout helps the matter, because the ground between them gets no rainfall at all.)
- lazide 5y agoKeep in mind, while yes this is a huge code issue mixing low voltage and high voltage - ‘it depends’ in a lot of jurisdictions on other elements. Following is for other folks running across this, in case it helps them. At least in California, I’m pretty sure it’s code compliant to use rated non-metallic conduit for outside high voltage runs for instance. That conduit is made of PVC. It’s the grey plastic electrical conduit at every hardware store (if branded as UV resistant/outdoor rated). Normal PVC pipe (for water) falls apart at too low a temperature and becomes super brittle when exposed to Sunlight surprisingly quickly. It’s a much better idea to use EMT or even ‘hard’ conduit depending on how it’s exposed, but it’s not required. EMF protection is nice, but I haven’t seen a such a requirement for power feeds in residential anyway. If using 3 phase and some industrial equipment I imagine you’d be a jerk to not do so, but most residential neighborhoods here have overhead unshielded lines anyway. Running to a separate detached building has a bunch of rules around grounding (for which you’ll find multiple mutually exclusive and conflicting codes across the county). Many areas don’t have lightning suppression rules though. Depending on exactly how the building is constructed (technically ‘mobile’ vs ‘fixed) also changes codes a lot. Running the equivalent of an extension cord to a ‘mobile’ structure (which can be functionally fixed) is perfectly fine as long as it’s GFCI protected for instance. Not that he did that. Ideally it would be a separate sub panel, grounded and protected as such, with proper rated conduit, etc. But the bar is a lot lower than what you’re saying if someone follows some basic guidelines. And can be done safely. But yeah, Article Author - you’re going to get someone killed. Jesus.
- hinkley 5y agoAh yes, I know about the grey PVC but spaced on it. Typically this is for external runs bolted to the side of a building though. Or at least, that’s almost all I ever see it used for. Can you use it for open air horizontal runs? Say between two buildings? Data you want shielded, for the reasons I stated. Stringing Ethernet between buildings often ends in tears.
- jefftk 5y agoI ran outdoor-rated cat6 in metal conduit between my house and shed, about 6 feet, and it has worked very well. What do you see as the problem?
- 404mm 5y agoI can comment on the second portion of this issue- never run Cat cables in parallel with electric cable. You are forcing low voltage and high voltage cables to share their electromagnetic field. That’s never a good thing. It can lead to unstable connection all the way to frying your Ethernet card.
- saxonww 5y agoGood news: he ran a 100ft cat6 cable so that he could plug in a wireless access point. His ethernet card should be fine.
- hamburglar 5y ago… but isn’t there still a risk to whatever devices are on both ends of that cat6? ie the access point and the head-end router or switch?
- amluto 5y agoForget the devices -- the risk is to people. If the insulation fails on the power cable and your network cable is insufficiently insulated, then your network cable could end up live. People generally avoid playing with hot power conductors, but no one takes any care to avoid touching network cables or, for that matter, the devices plugged in to network cables.
- dugmartin 5y agoIf they did short I think those tiny diameter wires in the cat6 would pretty much vaporize at household current.
- Tempest1981 5y agoImagine a short, so Cat6 is now at 120V. Then imagine someone repairing a Cat6 wall jack. Or a kid with a paper clip. Household current levels don't need to be flowing for it to be dangerous.
- 0xbadcafebee 5y agoYou just went from concerned citizen, to person with anger management issues lashing out. If your thoughts here were in good faith, you would help the author learn about code compliance so that he could make the necessary modifications and learn about the real-world consequences of not being in compliance. Instead you're making a threat to send code enforcement after him so that he can be punished for being ignorant. Please try to re-evaluate the feelings you have and ask yourself if there is a more positive, less harmful way to use those feelings.
- wbl 5y agoThe punishment for building code violations is death. The building code enforcement is a lot more lenient in comparison.
- jholman 5y agoHelp me to understand who dies when the rooflines overlap?
- jefftk 5y agoThat's a pretty big overstatement. For example, using insufficient insulation is a code violation, but it is not going to kill you.
- labster 5y agoUnless there’s an electrical outage during a big snowstorm or heat wave, and then lack of insulation can kill you. Maybe. Or the old people you sell your house to later. But sometimes you are correct. Like in writing where it’s best to know the rules of grammar before you start breaking them, it’s best to know why the building codes exist before you break them as a DIYer.
- kelnos 5y agoPoster seemed most upset specifically about the electrical issues. Those kind of things absolutely can kill you (or the next homeowner), or start a fire that can kill you, or your neighbors.
- amluto 5y agoIgnoring the type of conduit, there’s NM-B and CM (hopefully) in the same conduit. NM-B is not allowed outdoors (in “wet locations”) [0], and running your Ethernet cable and your power in the same conduit is no good. (Look up the code for feeders supplying structures — this is not even close to how it’s done. Maybe you can squeak by and consider this a structure supplied by a branch circuit, but there are still code requirements to pay attention to.) Also, that weather resistant barrier…. Imagine you are a drop of rainwater on the outside of that WRB, following gravity. Where do you go? Straight to the exposed OSB sticking out at the bottom. The sheathing is toast in heavy rain. [0] NM-B has paper running through it. Good old-fashioned water-wicking brown paper. If it gets a bit wet in a flooded conduit (hint: every outdoor conduit can be assumed to flood eventually), it will wick along the cable and never dry. edit: there is absolutely no requirement that buried conduit be metal. In my experience, despite code allowing various types of galvanized steel conduit to be buried, they tend to corrode severely long before whatever wires are in them are safely disconnected, creating a hazardous situation. You can use PVC, HDPE, etc.
- unethical_ban 5y agoWhat is NM-B? What is CM? What is WRB? What is OSB? If your point is to educate those without knowledge, a link or spelling some things out is helpful.
- alex_sf 5y agoThat's not the point. The point is that if you don't recognize the acronyms for non-metallic cable, comm multi, water resistant barrier, or oriented strand board, you should not be building a structure in a dense residential area.
- unethical_ban 5y agoOn one hand, I know there are good reasons for safety codes. On the other, it's my property and I want a covered workshop with a power outlet.
- ryandrake 5y agoThank you both. The number of "Wow this is so cool!" encouragement-replies here is pretty scary. Building a shed is definitely something most people can DIY, but please don't make it hazardous! And, at least make an attempt to look up local building codes. Even if conformance is not required for your particular application, they can be used as a reference for best practices. I believe some jurisdictions now occasionally check e.g. Google Maps to look for obvious things like sheds built too close to existing structures (which this one likely is), so it's possible he'll get an unrequested visit from code enforcement anyway.
- gjvc 5y ago> The way I did it was to run both wires inside a 3/4 inch PVC conduit using 14/2 electrical wiring + 100ft cat6 ethernet cable. should be SWA
- duxup 5y ago> I had to stop reading r/diy Same, I don’t want to rain on everyone’s parade, at the same time people should know “that might not be or ISN’T the way to do it…” I was also wary of what I suspected were a lot of “Here are my before and after shots I took.” Where they didn’t do the work.