2 ms·
Hey, those were fixable if you ran a UART to the jumpers, if this is the right one. Not entirely a brick! Also, firmware mistake = disk disappears from the bus
by toast0 5y ago
Hey, those were fixable if you ran a UART to the jumpers, if this is the right one. Not entirely a brick!
Also, firmware mistake = disk disappears from the bus is pretty common in enterprise SSD land. HPE did it twice, I've seen it on Intel drives, and I'm sure there are others I'm not remembering. Maybe Seagate was trying to be more enterprise... and at least their drives only failed to start up IIRC, if you were running them continuously it was fine (unlike the SSDs)
- p_l 5y agoI don't recall the vendor that Dell used, might have been intel, but I had NVMe drives that would displace clocks for half the connector on reboot unless you did a full powercycle...
- kevin_thibedeau 5y agoOnly certain models supported the fix via UART.