It's also more viable to be grid tied if your winter needs are more than X times your summer needs. My 6.6kW array generates roughly 3x what we need during summ
by PaulDavisThe1st 5y ago
It's also more viable to be grid tied if your winter needs are more than X times your summer needs. My 6.6kW array generates roughly 3x what we need during summer. But our home is heated in winter (at 6000' in New Mexico) using electrically powered air-source heat pumps (aka "minisplits") and that takes about 3x what we generate during the winter.
Adding either on-site storage capacity or sufficient additional panels to cover our winter needs really makes no sense. The storage capacity would have to be immense, because no matter how you slice it and dice it, we do not generate enough power to heat our home for several months (and that's with adobe and some passive design). The additional panels would take up a large amount of ground space, and result in us generating 9x our needs in summer.
I prefer to put my faith in the emergence of grid-scale storage solutions than try to solve this on a just-my-home level.
- ashtonkem 5y agoIf the grid wasn’t reliable, a hypothetical I know, it would probably be cheaper to switch over to a ground source heat pump rather than increase your panels by 3x. That would lower your winter electricity demand, albeit at the cost of significant capital expenditure.
- PaulDavisThe1st 5y agoDoes a ground source HP use that much less electricity than an air source HP?
- ashtonkem 5y agoYes, by far. It’s much easier to extract heat from ~55F ground water than from ~20F exterior air. Ditto for dumping excess heat into ~55F ground water than 90F exterior air. On average the water coming out of a geothermal loop will be more advantageous to work with than exterior air, which is why it’s a thing.