5 ms·
Yes, this is completely correct. I would add the wet bulb thermometer needs large evaporation area (so the sock cannot be too wet and definitely you can't put
by lmilcin 5y ago
Yes, this is completely correct.
I would add the wet bulb thermometer needs large evaporation area (so the sock cannot be too wet and definitely you can't put it in the bucket) and/or some airflow around it. Otherwise it will show some temperature between actual dry bulb and wet bulb temperatures.
In practice, nobody seriously uses wet bulb thermometers outside of school experiments because they are such a PITA. It is easier to just measure dry bulb temperature and humidity separately and then look up wbt in a table.
In general measuring temperatures correctly is a tricky business, what with temperature gradients in the objects you try to measure and the thermometer itself. I just recently needed to explain to a bunch of people why there is no such thing as "temperature in the sun" and that you can pick any temperature between WBT and around 5800K and it is going to be a correct temperature "in the sun" depending on properties and shape of the object you are trying to measure..
- bumby 5y ago>nobody seriously uses wet bulb thermometers outside of school experiments because they are such a PITA. It is easier to just measure dry bulb temperature and humidity How is humidity typically measured? I was under the assumption a hygrometer uses both dry and wet bulb measurements.
- lmilcin 5y agoWet bulb requires it to be... you know... wet. Not very practical to include in your electronics. I don't know exact method used but I can assure you, there is no water reservoir in any of my gadgets:)
- bumby 5y agoIt looks like I’m confusing a classic psychrometer with more modern ones. The modern ones still use absorption of water to change some physical property like capacitance or resistance but this is also why they need to be continually calibrated against a true dry/wet bulb hygrometer. My experience is that they tend to get out of cal quite often which can lead to bad scenarios, like if using enthalpy setback for air-handling
- lmilcin 5y agoWell, wet bulb thermometer works specifically by evaporating water and measuring temperature. Psychometer is completely different idea. Yes, measuring humidity reliably is a difficult problem as basically any other measurement that requires direct exposure of eroding/corroding components and fragile electronics to elements.
- bumby 5y agoI believe a psychrometer operates on the same principle. "A psychrometer, or a wet and dry-bulb thermometer, consists of two calibrated thermometers, one that is dry and one that is kept moist with distilled water on a sock or wick. At temperatures above the freezing point of water, evaporation of water from the wick lowers the temperature, such that the wet-bulb thermometer will be at a lower temperature than that of the dry-bulb thermometer. " https://en.wikipedia.org/wiki/Hygrometer https://en.wikipedia.org/wiki/Hygrometer The psychrometer just compares the wet and dry bulb temperatures to arrive at a relative-humidity value. I.e., it still operates on the principle of a wet-bulb thermometer.
- winthrowe 5y agoThe traditional 5 dollar analog hygrometer uses a paper/metallic strip coil: https://www.youtube.com/watch?v=jCUHDFYdG44 https://www.youtube.com/watch?v=jCUHDFYdG44
- bumby 5y agoI guess I was dancing around the point a bit. I meant the definition of relative humidity uses dry/wet-bulb comparisons but we use all sorts of more pragmatic calibrated proxies to measure it in practice.