3 ms·
Well, yeah, I’m with you, but, you don’t need a transformer. You need a HF short. That’s easy. You can hook up a common conductor any way you want, connect as m
by jl2718 5y ago
Well, yeah, I’m with you, but, you don’t need a transformer. You need a HF short. That’s easy. You can hook up a common conductor any way you want, connect as many independent channels as you want, put a big resistor from signal to ground at each terminal, and it works the same but smaller and lower power. Make the wire slightly resistive if you are concerned about reflection loops. I can’t think of a situation where signal couldn’t be improved by some kind of conduction.
- monocasa 5y agoAh, I thought you were talking about the area for the loops. The idea behind this is because running conductors through the substrate has its own issues that ironically makes it a lot more complicated than little transformers like this. It's all material science kind of stuff about how the extra steps to bond the layers conductively runs into yield issues. They also thermally flex in weird ways reminiscent of 2007 era BGAs that had problems with the shift to ROHS detaching themselves from boards. But way more fragile and you can't fix it by a run through the reflow oven. Obviously they've gotten past some of those issues in the past few years.