I'd like to see the next version of this spec go from 5A 50V to 2A 2000V. 5 Amps is getting into danger territory with cables that are bent a lot and heating i
by londons_explore 5y ago
I'd like to see the next version of this spec go from 5A 50V to 2A 2000V.
5 Amps is getting into danger territory with cables that are bent a lot and heating is concentrated in one high resistance area. Heating => melting => fire => deadly. Fire kills 10x more than electrocution.
2000V is also well into danger territory for humans, but we now have technology to make it human-safe for a child to gnaw through that wire while in operation and avoid injury. All that's needed is for the spec to require current leakage detection. As soon as 1 milliamp or more is unaccounted for between charger and device, you need to assume it's flowing through a child's tongue and power off within a few tens of microseconds.
That requirement means you need MOSFETs at each device (to be able to power off quickly), and to have capacitance control of the cable.
Every device needs to Verify that the device on the other end and cable does these things, so that nobody can make a cheap cable or widget which kills people.
- cma 5y agoIs there not technology to check changes in resistance? Even if it is in a small area as it heats it resistance should change much more rapidly than resistance changes when the entire cable heats up.
- londons_explore 5y agoCareful resistance monitoring could probably make 5 Amps sufficiently safe to avoid fires. But that's about the limit of it without the cable starting to get very bulky (due to needing thicker copper to keep heating down). If you want a cable spec which is never the limiting factor for whatever new gizmo you're trying to design, and therefore want a high power limit, then it's really the voltage that needs to increase, since it can go a lot higher before engineering the insulation gets hard.