Do you physically move your scanner? If so, how do you measure displacement accurately? Synthetic aperture requires a moving scanner, which it doesn't see you
by mikewarot 6y ago
Do you physically move your scanner? If so, how do you measure displacement accurately? Synthetic aperture requires a moving scanner, which it doesn't see you are doing.
Proper imaging requires keeping track of phase information, so you measure the distances more precisely.
It appears you're using 40Khz ultrasound transducers, so the wavelength should be about 8mm. You might want to try using less phase shift of the beam to tighten up the volume you're sweeping, and do it slower.
Try suspending a hard solid round object from 3 threads, and see how that responds. It should give you an idea of the "impulse" response in 3 dimensions, and thus a clue as to how to de-convolve the data.
- belzebalex 6y agoThe scanner is fixed, but the beam is moving. In a synthetic aperture, the beam is fixed but the scanner is moving, which should be equivalent for a first approximation. A "dot" like a hard solid round object returns a cardinal cosine in two dimensions centered on the object. I don't understand. Having more points by using smaller phase-shifting steps won't make my beam narrower?
- mikewarot 6y agoIf your array is phase coherent, your maximum resolution is going to be about 1/4 wavelength end to end, as an angle. Estimate 2mm for that 1/4 wavelength, and 200mm end to end on the array, the angle should be about 1/100 radians, or about 40 minutes of arc, if everything is working perfectly. Synthetic apertures start with phased arrays, such as yours, but take data from multiple positions, which are then correlated into virtual focus. If you were to attach your array to a board, butted up against a yardstick fixed to the desk, to keep the direction stable, you could move it sideways in 1cm intervals and collect enough data to do synthetic aperture, without spending a ton of money. 8)
- belzebalex 6y agoWhere is this 1/4 factor coming? I know that for a circular dish, the max resolution is 1.22lambda/(aperture size), so for my scanner it would be (1/4)lambda/(aperture size) Scanner is 100mm large, so that would do 2/100 radians. Will check up if that matches my simulations. Thanks for the infos on SAR! Will try doing that!
- mikewarot 6y ago>Where is this 1/4 factor coming? Guesswork... 40khz ultrasound has a wavelength of about 8mm. If your phase from end to end isn't at least 90 degrees, you don't have enough shift to form a beam with. I would imagine if you're clever, and your transducers don't drop off to fast on the sides, and you've got them fairly tightly constrained in X,Y,Z to a regular grid, you might be able to tweak out more resolution slightly off center, because the return phases will more quickly diverge as this angle increases.