> The completion report said, “While not an environmental remedy, because there are no significant risks, a VIMS consisting of a vapor barrier and a sub-slab ve
by amluto 6y ago
> The completion report said, “While not an environmental remedy, because there are no significant risks, a VIMS consisting of a vapor barrier and a sub-slab venting system has been designed and installed.” Installing these apparently could cost millions of dollars. It’s curious to me that Roux would plan to build four VIMS, or even build one, if they really thought VOCs were not an issue.
That sounds awfully like the way that ordinary houses are constructed, especially anywhere with (naturally occurring!) radium in or under the soil. When one builds a house with a slab foundation, one first builds a capillary break (a bunch of rocks with no fines, perhaps — this is an air-permeable layer), then applies a vapor barrier (polyethylene sheets), then pours the slab directly on the vapor barrier. The only thing special about sub slab venting is a pipe from the capillary break to the roof that may or may not be fan assisted. The goal isn’t so much to remove gas from under the slab as to reduce the pressure under the slab below the pressure above the slab such that gas doesn’t intrude.
All of this except the pipe is done regardless of soil gas concerns — water vapor coming through the slab destroys floor coverings.
I know basically nothing about commercial construction, and I could easily believe that vapor barriers are optional under parking lots.
Given that the VOCs in question are easily measurable in real time with a cheap sensor, it could be interesting to measure the VOCs at the lowest level of the parking lot over time. Some parking lots have CO (or CO2?) sensors that control exhaust fans. If there is less car activity at 3am, the fans could turn off, and that could have any number of effects.
(Also, the author doesn’t seem to have tried to distinguish between gasses coming from the building and gasses coming from under or outside the building. There is no actual evidence I saw in the article that the problem is a problem with the site. Heck, a building air intake being contaminated by gasses from the parking lot could introduce a fair amount of CO and NOx even if the levels were too low to set off a CO alarm. Builders mess up the airflow in buildings all the time.
Sadly, NOx sensors do not appear to be available at comparable prices to tVOC and CO sensors.