The electrician, drywall repair, and other skilled labor costs of running a thicker gauge wire to the kitchen from the circuit breaker would far outweigh the co
by lotsofpulp 6y ago
The electrician, drywall repair, and other skilled labor costs of running a thicker gauge wire to the kitchen from the circuit breaker would far outweigh the cost of the wire itself. By orders of magnitude.
- orra 6y agoFrom web searching, North America is 120V but two phases. So you could redo the socket to 240V without running new cable through your walls. But that's kinda academic if nobody sells kettles that have the North American 240V plug.
- mlyle 6y ago> From web searching, North America is 120V but two phases. So you could redo the socket to 240V without running new cable through your walls. You'd need an extra conductor of wire than is there in the cable for a standard 240V outlet. (Hot1, Hot2, Neutral, Gnd). You can run a Hot1/Hot2 240V circuit with existing 14/2 romex, but odds are that whatever feeds the outlet in your kitchen also feeds many other outlets, and you don't want them all to be 240V. Note North America doesn't use ring circuits like the UK.
- sjg007 6y agoThe Japanese hot water things basically solve this problem too by maintaining hot water all the time.
- orra 6y agoConvenient but inefficient.