> Otherwise accidents will be disastrous for plant operators What's going to go wrong? I've seen talks that breaches will be rapidly cooling and will be contai
by poopoopeepee 6y ago
> Otherwise accidents will be disastrous for plant operators
What's going to go wrong? I've seen talks that breaches will be rapidly cooling and will be contained by a modest amount of concrete.
- pfdietz 6y agoPlasma disruptions https://www.jp-petit.org/NUCLEAIRE/ITER/ITER_fusion_non_controlee/Wurden_en.pdf https://www.jp-petit.org/NUCLEAIRE/ITER/ITER_fusion_non_cont...
- ohiovr 6y agoField quenching of the super conducting coils. The stronger the field the worse it can be when it collapses.
- willis936 6y agoQuenching is less of a concern with HTS coils. They are operated with liquid helium for higher critical current. The HTS is embedded in copper. One argument going on right now is insulated vs uninsulated coils. Insulated are the norm, but uninsulated are virtually impossible to damage from quenching. The copper is a virtual open when the core has zero resistance. When the core quenches then suddenly the windings are all parallel and the coil turns into a single turn copper coil that immediately dumps the current.