> This will take a long time, since you will be writing to basically this whole drive as part of distributing its spare space. (Plus probably shuffling chunks a
by mbreese 6y ago
> This will take a long time, since you will be writing to basically this whole drive as part of distributing its spare space. (Plus probably shuffling chunks around between many other drives)
Yes. With the caveat that you'll be *reading* from all of the disks to satisfy those writes. In a traditional setup, you'd have multiple striped raidz{,2,3} vdevs. When you swap in a spare, you're only pulling reads from the disks in the same vdev. This will drive the performance from this vdev to the ground. In this draidz setup, you'll be pulling from all of the disks, so the entire pool is stressed at the same rate.
I think the way I'm starting to think about it is that each drive has X amount of spare capacity or buckets. But they are otherwise used. When a drive goes out, the primary data from that drive is distributed across the array to the already-in-place spare capacity. So, yes, after the primary data is mirrored out, the pool is no longer degraded. But, I think the point being made here is that you'll still want to replace the drive, which will still cause *that* drive to be fully written.
- jsmith45 6y agoRight, the free space buckets are a fine analogy. They are conceptually similar in some ways to the free space in the hot standby drive. I don't think from a data safety or performance perspective pre dRAID vdev really differ too terribly much from raid 50 setups. (They do differ greatly in administrative flexibility, versus the insanely rigid approachs of traditional hardware raid). But yeah, after replacing the failed drive, ideally dRAID would basically do just what it did after drive failure in reverse. (End result: No longer having any drives holding data for a different vdev than they belong to). Obviously this means writing basically that whole disk, and reading from potentially every disk. But as you mention you are spreading the load out across the whole array, hopefully reducing the overall impact, and being less likely to stress any drive into dying.