The problem here is the high tomorrow in Dallas is supposed to be about 10°F. The typical winter high for Dallas is a bit below 60°F. This means that the demand
by jcranmer 6y ago
The problem here is the high tomorrow in Dallas is supposed to be about 10°F. The typical winter high for Dallas is a bit below 60°F. This means that the demand for heating is about 4-6× what it normally would be for winter.
- adrianN 6y agoEnergy loss is strongly supralinear in the temperature gradient, so it's probably a lot more than that.
- airhead969 6y agoTime-dependent solutions to temperature change across a gradient are exponential decay functions that solve diff eqs based on Newton's law of cooling. It depends mostly on the insulation and the temperature difference. While it is 10 F outside, the central heating system for my apartment in a 6-story building cannot maintain temperature. It is 66 F and gradually falling. I would guess it would be 2.5kW running 24/7.
- jacquesm 6y ago25KW more likely
- tgtweak 6y agoProbably closer to this than 2.5kw. 2.5kw on a decently modern heat pump should be providing 25k btu. About enough to heat a 2000sqft house ~50f over ambient.
- NickNameNick 6y agoI have a 2.4kW heater in my bedroom...
- skinkestek 6y agoJust in case anyone is about to miss this detail: That heater probably doesn't run continously. For a well designed shared system you can get away with less than n x what an individual unit needs. (That said, I too guess 2.5kW is too small for what GP mentioned.)
- ChrisIsTaken 6y agoEnergy loss through an insulator is exactly linear to temperature. The problem is that people who would have otherwise tolerated 50F temperatures without heating by putting on a sweater are pulling their old oil column heater out of the storage.
- adrianN 6y agoOh you're right.
- makomk 6y agoOne other problem is that one of the ways people have been making their heating more efficient is by using heat pumps, and their efficiency gain drops off with lower temperatures until they become no more efficient than the resistive heaters they replaced during the kind of unusually cold weather Texas is apparently seeing. This makes the peak to average power usage problem even worse.
- ece 6y agoMore modern heat pumps can be efficient at up to around -10 degF[1]. Higher efficiency federal/local rebates are not bad across the US, so I wouldn't be surprised if these were installed in some TX homes. It's still a capacity problem if average use is 10hr/day instead of 2hr/day and your house has no gas furnace heating. I would guess most TX (Dallas/Austin) homes probably do have a gas furnace, but maybe not in coastal/south TX (Houston). [1] https://daikincomfort.com/go/aurora/ https://daikincomfort.com/go/aurora/
- PeterisP 6y agoAre their heat pumps linked to outside if their efficiency is so affected? The models I see generally pipe underground, where the temperature is mostly stable and isn't affected by a week of unusually cold weather.
- sokoloff 6y agoThe overwhelming majority of heat pumps across the US are air-source (rather than ground-source), so "yes, overwhelmingly".
- da_big_ghey 6y agoEnergy usage is superlinear below a certain point. As I recall, about 25% of homes in Texas use heat pumps. but below 30-ish degrees, heat pumps don't work and they have to switch to resistance-based heating So, demand will start rising a whole lot faster.
- mmaurizi 6y agoThere are newer heat pumps that work below 30 degrees, but they're more expensive and not typically used in Texas for obvious reasons.
- whatever1 6y agoBut on the other hand there are only so many hours in a day to run your HVAC/space heater. So from 8 hours per day, it can go worst case to 3x.
- stdbrouw 6y agoHm, heating is either switched off/on depending on a thermostat ("bang-bang") or in more sophisticated systems is regulated according to need (modulating control). It might be on 24/7 regardless of whether it's hot or cold, but it's not going to use the same amount of power.
- brianwawok 6y agoMy furnace, which is common in mid level units, is two phase. It’s off, low, high. Basically it starts by modulating off and low. Once low is on 24/7 and it needs more heat, it modules low/high. At peak heat it’s just high all the time. Upside to being in Indiana is our furnaces are made for this. I think I can keep my house at 70 down to like -30F outside. It’s a pretty expensive furnace though, wouldn’t make sense in Texas.
- bombcar 6y agoEven a cheap thirty year old furnace can do that - it was able to keep my house at 80° during the -40 (no need to specify; they’re the same that low!) last year. I actually intentionally drove it to 80 to give me thermal mass if needed but it turned out not to be necessary. Burning gas is insanely thermodynamically active.
- stdbrouw 6y agoAs an addendum, this winter I unfortunately found out that, at very low temperatures, the limiting factor might be the furnace, but it might also be the capacity of the radiators (or underfloor heating, or whatever) to shed heat. Tiny radiators or highly spaced underfloor pipes and it won't matter how fancy your furnace is, there's only so much heat it can distribute.
- tgtweak 6y agoSeems to be a combination of many things (a perfect storm...): • Dwellings are not insulated to the same level as their northern counterparts. Over 60% of houses in Texas have single pane glass. • Texas seems to rely substantially on heat pumps for residential heating, with fallback to resistive heating. At 10°f very few heat pumps can supply sufficient heat to keep even a decently insulated house properly heated - my guess is that many are using 2-3x less efficient resistive heaters at night. • Heating peak demands tend to be correlated with the longest time since the sun was last shining... This bodes poorly for solar supply and also self generators - even those with battery backup. • Texas typically imports from neighboring states... Most of which are in a similar irregular climate. • Heating requirements for a building vs exterior temperature is non-linear, as are heat pump efficiencies. This is especially pronounced with poor insulation factor. To put it into context, Quebec has ~46,000MW of peak electrical production capacity for a population of 8.4M. during cold winter days (-30°f) it uses all of that capacity and becomes a net-importer. In Summer months, it uses 1/3 of this. Texas had peak electrical production capacity of 37,600MW for it's population of 29M.
- ubermonkey 6y agoGreetings from Texas. Yeah, all that is true. You build based on how things usually are, or at least usually WERE when the dwelling was built. I live in Houston -- very close to downtown, so I'm only about 50 miles from the Gulf of Mexico. This makes it VERY FUCKING WEIRD INDEED that my entire yard is covered in snow, and it is 16F outside. This is NOT Houston weather. It's almost unprecedented -- it's certainly never been anywhere NEARLY this cold in the 26 years I've lived here, and the idea that we really won't be above 32F (0C) for a material amount of time until SATURDAY is really really nuts. In a normal Houston winter, by contrast, we MIGHT see 3-4 nights that freeze. We go years without needing to wrap plants, and I've never bothered to wrap outside pipes before. (Outlying areas to the north and especially northwest of the urban core get as much as 10 degrees F colder, but even so it's not a regular thing.) So yeah, we're all built here for cooling and not heating. Ambient air temp outside is rarely more than 95, so getting your house to 78 is pretty attainable. But when we get cold snaps, WE certainly notice in our house, which is a relatively new (1997) 3-story townhouse (very vertical; it's about 1800 sq. ft. or 167m^2). It's just not set up to heat evenly or well. The first problem is just distribution. Our house has a modern 'open' style floorplan, with soaring ceilings in the middle (living) floor. Heat, of course, rises. The upshot is that if you set the thermostat to warm the lower 2 floors to, say, 65F, the 3rd floor main bedroom will be intolerably warm and dry. As a consequence, a window in our bedroom is open about 2" all winter. The other gotcha in our house is the floor in the first level, where I have my office (I work from home). It's a stained concrete floor, which is great in the summer because it helps keep the room nice and cool. Unfortunately, it does exactly the same thing in the winter. I'm wearing thick wool socks and long underwear in here now, even though I have a plug-in radiator to supplement the central heating. Actually, the radiator -- a Delonghi; it works great -- would probably be enough IF the windows were better sealed. My desk is up against a window. My legs feel cold all day in weather like this (well, in cold weather; there hasn't been any weather LIKE THIS before), to the point that last week when it was much warmer (45F during the day) I was wearing sweatpants over jeans. The house is wonderful and comfortable and attractive. It works GREAT for the vast majority of our weather. It just gets drafty in the winter. And, of course, today I'm concerned that we're going to get rolling outages. Whooo! At least we have a fireplace. (People laugh about it, but in all honesty having a fire is the easiest way to make the living area comfy without overheating the top floor, just based on where the heat goes. If the house was a little bit bigger, I suspect it would've come with 2 climate control units and proper zoning, which would help a LOT, but as is: just one big zone.)
- mandelbrotwurst 6y agoSort of - to understand how extreme a 10 degree high really is we should be comparing it to the high on the typical coldest day of the year, and then consider how many deviations away from that number this event is, not just how it compares to a typical winter day. Probably want to consider the low temps as well.