2 ms·
The difference is urgency, and knock on effects. If your system is designed for hot swap of failed disks, but 1% of the time, you need to reboot the system for
by toast0 6y ago
The difference is urgency, and knock on effects.
If your system is designed for hot swap of failed disks, but 1% of the time, you need to reboot the system for the new disk to be detected; predictive replacement lets you move traffic off the system at a convenient time to do the swap (when traffic is low, and operations staff isn't super busy). Predictive replacement can be deferred more easily, because the system is still working; maybe you can batch it with some other maintenance.
A surprise failure needs to be dealt with in a more timely fashion.
In my experience (which I didn't write a blog post for), monitoring the right SMART values and doing predictive replacement eliminated most of the surprise failures for spinning drives. SSDs had less failures, but I wasn't able to find any predictive indicators; they generally just disappeared from the OS perspective.
- jeffbee 6y agoYou are trading off cost, though. According to that paper I referenced, the SMART reallocated sector count is just binary (the critical threshold is 1 sector). Drives with non-zero counts are much more likely to fail but 85% of them are still in service a year later. If you proactively replace them you may indeed have avoided some surprise failures but it's actually not a great deal more effective than replacing drives randomly, and it costs money. Also we haven't even discussed the online disk repair phenomenon, in which you take a "failed" disk, perform whatever lowest-level format routine the manufacturer has furnished, and get another 5 years of service out of it. This is done without ever touching it.