3 ms·
Reallocated sectors is pretty good, but I'd also look at pending and offline uncorrectables to get a potential earlier warning. I've seen some drives that were
by toast0 6y ago
Reallocated sectors is pretty good, but I'd also look at pending and offline uncorrectables to get a potential earlier warning.
I've seen some drives that were apparently working fine with about 1000 reallocated sectors; and the smart firmware usually indicates a maximum of quite a few more than that, so if you replace at 100 problem sectors, I would consider that 'predictive' replacement. It's debatable of course; something that predicted failure based on changes in data transfer (that presumably precede sectors being flagged), would be a bigger predictive step, but I never got that far in modeling; using flagged sector counts was enough to turn unscheduled drive failures into scheduled drive replacements for me.