5 ms·
HVs are typically 200V/200A ~50kW, Nissan Leaf, Tesla, other various BEVs are 400V/1-2kA ~500kW, except I think Porsche and NIO is 800V/0.5-1kA ~500kW, higher o
by numpad0 6y ago
HVs are typically 200V/200A ~50kW, Nissan Leaf, Tesla, other various BEVs are 400V/1-2kA ~500kW, except I think Porsche and NIO is 800V/0.5-1kA ~500kW, higher or lower within classes depending on models/generations.
They always make it into parallel blocks of series cells that each has the nominal pack voltage.
By the way you don’t want 3.7V/135kA cable running next to you!