Crosstalk is when two wires are close together, one induces a voltage in the other (it's how transformers work). The trouble with house wiring is if you run a p
by WalterBright 6y ago
Crosstalk is when two wires are close together, one induces a voltage in the other (it's how transformers work). The trouble with house wiring is if you run a phone line parallel and close to an A/C line, it will induce a 60 cycle hum in the phone line, which will drive you utterly mad.
The electrician was installing the cat3 phone wires in the same holes as the A/C wires. It was guaranteed to induce a hum.
The correct approach is to keep the low voltage wires as far from the A/C as you can, and if they cross, keep the crossing at 90 degrees. Don't run them in parallel unless they are separated by feet (plural). If you have to, you can run them in grounded metal conduit as a shield.
I probably went overboard on this, but doing it inadequately meant 60 cycle humming on the phone lines and an utterly ghastly bill to rip the walls up and fix it.
He also was installing cat3 (POTS cable) and R59 cable (1970's cable TV stuff). I pulled that all out and threw it in the trash, putting in cat5 (cat5e and cat6 are better, but weren't available then) and quad-shielded RG6 cable.
Getting the best cable available cost maybe 20 or 30 dollars more, so it's crazy not to do it. The network and cable speeds have all increased dramatically since I installed it, and the cables have all worked like a champ.
Even the cat5 cables are happily carrying gigabit Ethernet.
I have a couple plugboards in the basement where all the wires terminate.
I did the whole thing for less than a grand. If an electrician had done it, it likely would have been 10 or 20x more.
- hondadriver 6y agoHere in The Netherlands and probably other parts of Europe, you are not allowed to run electricity and network or phone cables through the same tubes. Also the number of wires allowed in a single tube is limited. Many houses have concrete walls, floors and ceilings, so you don't run extra tubes easily... Reconfiguring switches is next to impossible and via existing switch wires you can dim/switch the lights but not change colour(temperature). So here the original switches are removed and the connection is bridged (always on) and battery/kinectic powered ZigBee switches control the lights directly, even if the gateway is down.
- bhickey 6y agoConduit isn't very common in US residential construction. Electricians will generally cut a hole in the drywall, drill a hole in the floor plate and tack the cabling to the framing.
- ur-whale 6y agoIn houses than are typically built with a wooden frame. From a European pov, that sounds like a recipe for fire.
- michaelt 6y agoAmericans love building single-storey detached houses on big lots. And when they build an upper floor, they love complex roof systems where almost every upper floor window has a first floor roof or porch below it. This means problems like fires spreading to adjacent buildings and fires trapping people where they can't escape are much reduced; you'd never see a repeat of the great fire of London in an American suburb because there's practically a fire break between every single home. This is made affordable by America's vast tracts of land and high rates of car ownership.
- maxerickson 6y agoI'm curious how you'd compare the Great Chicago Fire (that happened ~200 years later)? https://en.wikipedia.org/wiki/Great_Chicago_Fire https://en.wikipedia.org/wiki/Great_Chicago_Fire The same day, a forest fire ravaged a number of small towns: https://en.wikipedia.org/wiki/Peshtigo_fire https://en.wikipedia.org/wiki/Peshtigo_fire
- ComputerGuru 6y agoI think that is very location dependent. Here in the Midwest, Romex still isn’t a thing and most residential construction still requires (effectively or otherwise) 1/2” electrical conduits for all high voltage wiring. Older construction might be the horrible BX/AC instead.
- 6y ago
- shawnz 6y ago> Here in The Netherlands and probably other parts of Europe, you are not allowed to run electricity and network or phone cables through the same tubes. Presumably that is not because of interference concerns but because of the danger of mixing high voltage and low voltage circuits in the same conduit, right? As others have noted, conduit isn't usually used in houses in the west.
- hondadriver 6y agoYes, it is for safety reasons.
- stinos 6y agoSorry should have been more clear; I'm an eletronics engineer so I know what crosstalk is, it's just that I didn't understand how this would be an actual problem with CAT5. Phone line, that's something else though. If an electrician had done it, it likely would have been 10 or 20x more. Hmm, that is like twice the amount one would typcially pay here. Still, don't froget the working hours you put in there :) plus the fact that usually technicians get their materials for cheaper than you do (also because in my case it's only 6% VAT instead of 21%). I did many such calculations when renovating and for some things it was actually cheaper to get a technician.
- ur-whale 6y agoThey're maybe getting it for cheaper than you do, but if you think that's what they're actually charging you, you're deluded. The typical electrician gets it indeed for cheaper than market rate, then charges it to you retail rate plus 20% to account for the "trouble" of sourcing and purchasing it.
- stinos 6y agoif you think that's what they're actually charging you, I never claimed that. The typical electrician Maybe you rather mean 'the typical electrician I met' or so because I know for a fact the rest of that sentence does not apply to the ones I met myself.
- parliament32 6y agoFrom my experience in trades, you just double the price of all materials.. which conveniently is roughly the same price homeowners will see if they spot-check at Home Depot.
- baybal2 6y agoIndeed, UTP5 is more or less crosstalk immune within for practical uses, STP5+ moreover so.
- petre 6y agoThat's an easy one. Switch on the light, network disconnects. We had this happen at our office. There's obviously much more happening on an electrical network other than 50/60 Hz, like transient response to switching loads on and off, RF noise from spark loads, dimmers etc.
- tinus_hn 6y agoAlthough that hum is annoying on analog signals, it has no effect on digital high speed communications. Still I agree it isn’t worth the headache of issues to save $20 and it’s more futureproof to use better cables.
- ficklepickle 6y agoIt has no effect unless it lowers the SNR too much and errors can't be corrected. Try wrapping RG6 a few times around a thick, active AC line. I saw that a few times back when I was a field tech.
- hnarn 6y agoJust out of curiosity, would shielded cat-cables help in a situation where you have it next to A/C wires?
- walshemj 6y agoIt would have to be a very noisy line and probably not the average house ac - this is from what my CCNA instructor commented. They also said that stp is a lot harder and expensive to install.
- shawnz 6y ago> if you run a phone line parallel and close to an A/C line, it will induce a 60 cycle hum in the phone line Isn't twisting the pairs supposed to prevent that? Isn't that what makes it feasible to run telephone lines on the same poles as electricity, thus allowing the POTS system to be practical?
- TheOtherHobbes 6y agoYes, it is. Also true for data. The problem is that common mode rejection is limited for unshielded pairs, so it works - but not perfectly. POTS is legacy now, so I'm not sure how much of a consideration it is for modern builds. There are safety issues with running network and power cables close to each other, but generally on small domestic systems crosstalk between data and power shouldn't be a serious problem. The exception is if you have a lot of hash on the power lines from USB chargers, unfiltered noisy motors, or white goods that generate both digital and analog noise. Ferrites or other kinds of filtering can help. So can using shielded cat cable.
- bleepblorp 6y agoI would seriously question the overall competence of any electrician who ran any low voltage cable in direct contact with AC power cables. This practice is not permitted by the electrical code. An electrician who does not respect that code requirement might be cutting corners with the code in other areas, too. While the level of knowledge among electricians regarding network wiring is gradually increasing, the conventional wisdom for anyone who wants network wiring installed professionally is to hire a contractor that specializes in low voltage wiring.
- WalterBright 6y agoThis was 20 years ago and the general contractor thought I was nuts to pre-install all this cabling. This all changed a year later, and network cables pre-installed became normal.