> but the disadvantage of increasing the risk if one is electrocuted. Avoiding this was one of the design parameters of the "Schucho" plug design that is reaso
by gumby 6y ago
> but the disadvantage of increasing the risk if one is electrocuted.
Avoiding this was one of the design parameters of the "Schucho" plug design that is reasonably standard across Europe. You'll note the three prong plug has a longer ground that makes a connection before any hot one does. The US three prong is supposed to work that way too but the ground pin isn't long enough.
I continue to be amazed how many devices still ship with only two prong plugs (everywhere: Europe, North America, Australia...) even if those prongs are polarized.
- kalleboo 6y ago> I continue to be amazed how many devices still ship with only two prong plugs (everywhere: Europe, North America, Australia...) even if those prongs are polarized Because most devices these days have plastic cases (Class II double insulated), so there's nothing metal to touch to get shocked even in the case of a fault. That coupled with how GFCI/RCDs are being widely adopted as well leads to grounding not being as important.
- kelnos 6y agoI'm (mostly) with you on the plastic casing, but in general (in the US at least) you only see GFCI in kitchens and bathrooms. Meanwhile I'm sitting 2 feet away from a nearly completely metal lamp with a two-prong plug.
- lucioperca 6y agoFind this very scary not having RCD on some plugs even with 120 Volts. Sure 240v with RCD will give you a massive shock but still will very unlikely kill you. No RCD on the other hand can be fatal on 120V: https://edition.cnn.com/2017/07/18/health/teen-bathtub-electrocuted-text-trnd/index.html https://edition.cnn.com/2017/07/18/health/teen-bathtub-elect...
- jhoechtl 6y agoIts Schuko, short for SCHutzKOntak, "contacts and ground".
- amaccuish 6y agoIf we're being pedantic, it stands for "Protection contact"